@@ -0,0 +1,104 @@
|
||||
"""add uuid column to meter table
|
||||
|
||||
Adds a stable ``uuid`` (UUID v4 string) column to the ``meter`` table so that
|
||||
each meter epoch has a durable identity anchor suitable for use as an HA
|
||||
Discovery ``unique_id``.
|
||||
|
||||
**Migration strategy (SQLite-safe)**:
|
||||
|
||||
SQLite does not support adding a NOT NULL + UNIQUE column to a non-empty table
|
||||
in a single ``ALTER TABLE ADD COLUMN`` statement (adding a NOT NULL column
|
||||
without a default value is rejected if the table already has rows). The
|
||||
safe approach used here is:
|
||||
|
||||
1. Add ``uuid`` as a **nullable** column (SQLite allows this).
|
||||
2. **Back-fill** every existing ``meter`` row with a distinct ``str(uuid4())``
|
||||
value. Each row gets its *own* random UUID — not a shared value — so the
|
||||
subsequent UNIQUE constraint is satisfied.
|
||||
3. Use ``batch_alter_table`` (which re-creates the table under the hood in
|
||||
SQLite) to alter the column to ``NOT NULL`` and add a UNIQUE constraint.
|
||||
|
||||
**Idempotency**: only rows where ``uuid IS NULL`` are back-filled; rows that
|
||||
already have a uuid (e.g. from a repeated upgrade after a partial failure) are
|
||||
left untouched.
|
||||
|
||||
**Audit**: after back-fill, the count of rows with ``uuid IS NULL`` must be
|
||||
exactly zero; if not, the migration raises ``RuntimeError`` and rolls back.
|
||||
|
||||
**Data safety**: this migration is additive only — no existing rows are deleted
|
||||
or overwritten; it only adds a new column and fills it in.
|
||||
|
||||
Revision ID: 20260625_14_meter_uuid
|
||||
Revises: 20260625_13_meter_table
|
||||
Create Date: 2026-06-25 00:00:00.000000
|
||||
"""
|
||||
|
||||
import uuid as _uuid
|
||||
from typing import Sequence, Union
|
||||
|
||||
import sqlalchemy as sa
|
||||
from alembic import op
|
||||
|
||||
revision: str = "20260625_14_meter_uuid"
|
||||
down_revision: Union[str, None] = "20260625_13_meter_table"
|
||||
branch_labels: Union[str, Sequence[str], None] = None
|
||||
depends_on: Union[str, Sequence[str], None] = None
|
||||
|
||||
|
||||
def upgrade() -> None:
|
||||
conn = op.get_bind()
|
||||
|
||||
# ------------------------------------------------------------------ #
|
||||
# 1. Add uuid as a nullable column. #
|
||||
# ------------------------------------------------------------------ #
|
||||
with op.batch_alter_table("meter", schema=None) as batch_op:
|
||||
batch_op.add_column(
|
||||
sa.Column("uuid", sa.String(length=36), nullable=True)
|
||||
)
|
||||
|
||||
# ------------------------------------------------------------------ #
|
||||
# 2. Back-fill: assign a distinct UUID to every row that has #
|
||||
# uuid IS NULL. Each row gets its own random value so that the #
|
||||
# subsequent UNIQUE constraint is satisfied. #
|
||||
# ------------------------------------------------------------------ #
|
||||
rows = conn.execute(sa.text("SELECT id FROM meter WHERE uuid IS NULL")).fetchall()
|
||||
for (meter_id,) in rows:
|
||||
new_uuid = str(_uuid.uuid4())
|
||||
conn.execute(
|
||||
sa.text("UPDATE meter SET uuid = :uuid WHERE id = :mid"),
|
||||
{"uuid": new_uuid, "mid": meter_id},
|
||||
)
|
||||
|
||||
# ------------------------------------------------------------------ #
|
||||
# 3. Audit: verify no rows remain with uuid IS NULL. #
|
||||
# ------------------------------------------------------------------ #
|
||||
null_count_row = conn.execute(
|
||||
sa.text("SELECT COUNT(*) FROM meter WHERE uuid IS NULL")
|
||||
).fetchone()
|
||||
null_count: int = null_count_row[0] if null_count_row else 0
|
||||
|
||||
if null_count != 0:
|
||||
raise RuntimeError(
|
||||
f"meter.uuid back-fill audit failed: {null_count} meter row(s) still have "
|
||||
"uuid IS NULL after back-fill. Migration aborted to protect data integrity."
|
||||
)
|
||||
|
||||
# ------------------------------------------------------------------ #
|
||||
# 4. Alter column to NOT NULL + UNIQUE (requires batch on SQLite). #
|
||||
# batch_alter_table re-creates the table, so the UNIQUE constraint #
|
||||
# and NOT NULL are applied atomically. #
|
||||
# ------------------------------------------------------------------ #
|
||||
with op.batch_alter_table("meter", schema=None) as batch_op:
|
||||
batch_op.alter_column(
|
||||
"uuid",
|
||||
existing_type=sa.String(length=36),
|
||||
nullable=False,
|
||||
)
|
||||
batch_op.create_unique_constraint("uq_meter_uuid", ["uuid"])
|
||||
|
||||
|
||||
def downgrade() -> None:
|
||||
# Drop the UNIQUE constraint and the uuid column (batch on SQLite).
|
||||
with op.batch_alter_table("meter", schema=None) as batch_op:
|
||||
batch_op.drop_constraint("uq_meter_uuid", type_="unique")
|
||||
batch_op.drop_column("uuid")
|
||||
@@ -79,6 +79,24 @@ router = APIRouter(prefix="/api/energy", tags=["api-energy-meters"])
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
|
||||
def _trigger_discovery_republish(session: Session) -> None:
|
||||
"""Call publish_discovery after a meter write operation (best-effort).
|
||||
|
||||
No-op if MQTT / discovery is not enabled or the broker is not connected
|
||||
(publish_discovery guards internally). All errors are swallowed so that a
|
||||
discovery failure never breaks the API response.
|
||||
|
||||
Must be called **after** db.commit() so that publish_discovery sees the
|
||||
final committed state of the meter table when it rebuilds the catalog.
|
||||
"""
|
||||
try:
|
||||
from app.services.ha_discovery import publish_discovery
|
||||
|
||||
publish_discovery(session)
|
||||
except Exception:
|
||||
logger.exception("_trigger_discovery_republish: publish_discovery raised an error")
|
||||
|
||||
|
||||
def _get_meter_or_404(db: Session, meter_id: int) -> Meter:
|
||||
"""Return the meter with the given id or raise 404."""
|
||||
meter: Optional[Meter] = db.get(Meter, meter_id)
|
||||
@@ -185,9 +203,10 @@ def declare_energy_meter(
|
||||
|
||||
**Retroactive recompute**: if ``started_at`` is in the past, billing
|
||||
records from that point forward are re-judged via ``recompute_range`` to
|
||||
reflect the new meter attribution. The response includes the count of
|
||||
recomputed periods in ``recomputed_periods`` (not part of ``MeterResponse``
|
||||
— the recompute is transparent; callers should re-fetch costs if needed).
|
||||
reflect the new meter attribution. The recompute is transparent — the
|
||||
response body is the created meter (``MeterResponse``) only and does **not**
|
||||
include a recompute count; callers should re-fetch costs if they need the
|
||||
updated totals.
|
||||
"""
|
||||
started_at_utc = _localize_started_at(body.started_at)
|
||||
|
||||
@@ -216,6 +235,11 @@ def declare_energy_meter(
|
||||
db.commit()
|
||||
db.refresh(new_meter)
|
||||
|
||||
# Trigger HA discovery re-publish so the new active meter's energy-cost
|
||||
# device/sensor configuration is pushed to Home Assistant. Best-effort:
|
||||
# failures are logged and swallowed; the API response is not affected.
|
||||
_trigger_discovery_republish(db)
|
||||
|
||||
logger.info(
|
||||
"POST /api/energy/meters: declared %r meter id=%d label=%r started_at=%s",
|
||||
body.commodity,
|
||||
@@ -293,6 +317,11 @@ def patch_energy_meter(
|
||||
db.commit()
|
||||
db.refresh(meter)
|
||||
|
||||
# Trigger HA discovery re-publish so label renames on the active meter
|
||||
# propagate to the HA device name. Best-effort: failures are logged and
|
||||
# swallowed; the API response is not affected.
|
||||
_trigger_discovery_republish(db)
|
||||
|
||||
logger.info(
|
||||
"PATCH /api/energy/meters/%d: updated meter label=%r started_at=%s",
|
||||
meter_id,
|
||||
|
||||
@@ -488,6 +488,7 @@ def test_read(
|
||||
device.port,
|
||||
device.unit_id,
|
||||
[{"start": b.start, "count": b.count} for b in profile.blocks],
|
||||
function_code=profile.function_code,
|
||||
)
|
||||
payload: dict[str, Any] = decode_profile(profile, registers)
|
||||
return ModbusTestReadResponse(ok=True, payload=payload)
|
||||
|
||||
+73
-15
@@ -27,6 +27,7 @@ from __future__ import annotations
|
||||
|
||||
import logging
|
||||
from dataclasses import dataclass, field
|
||||
from datetime import timedelta
|
||||
from typing import Any, Callable, Optional, Protocol
|
||||
|
||||
from sqlalchemy.orm import Session
|
||||
@@ -369,16 +370,44 @@ register_provider(_modbus_provider)
|
||||
# Energy Cost provider
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
# *_today 当日窗口翻天的宽限:本地午夜后 5 秒才切到新的一天,避免在 00:00:0x 把
|
||||
# 归零后的值发出去、被慢几秒的 HA 钟记成前一天的 23:59:59(归错小时桶)。
|
||||
_TODAY_RESET_GRACE = timedelta(seconds=5)
|
||||
|
||||
|
||||
def _energy_cost_provider(session: Session) -> list[ExposableEntity]:
|
||||
"""Enumerate ExposableEntity objects for the energy cost subsystem.
|
||||
|
||||
Produces 4 sensor entities grouped under a single HA device "Energy Cost":
|
||||
Produces 6 sensor entities grouped under a single HA device whose identity
|
||||
is anchored to the **current active electricity meter**:
|
||||
|
||||
- ``buy_price_now`` — current effective buy price (EUR/kWh or local currency).
|
||||
- ``sell_price_now`` — current effective sell price (EUR/kWh or local currency).
|
||||
- ``import_cost_total`` — cumulative import cost (total_increasing, monetary).
|
||||
- ``export_revenue_total`` — cumulative export revenue (total_increasing, monetary).
|
||||
- ``import_cost_total`` — cumulative import cost (total, monetary).
|
||||
- ``export_revenue_total`` — cumulative export revenue (total, monetary).
|
||||
- ``import_cost_today`` — today's import cost (total_increasing, monetary).
|
||||
- ``export_revenue_today`` — today's export revenue (total_increasing, monetary).
|
||||
|
||||
Active meter requirement
|
||||
------------------------
|
||||
**If no active electricity meter exists, the provider returns ``[]``.**
|
||||
No energy-cost entities are exposed to HA until a meter has been declared.
|
||||
This prevents spurious sensor creation with an undefined device identity.
|
||||
|
||||
HA device identity (换表 → 新 sensor)
|
||||
--------------------------------------
|
||||
``identifiers[1]`` is set to the active meter's **uuid** (not the fixed
|
||||
string ``"energy-cost"``). ``ha_discovery.py`` uses ``identifiers[1]`` as
|
||||
the MQTT node_id and as part of the ``unique_id`` for every entity.
|
||||
Declaring a new active electricity meter produces a new uuid → new node_id /
|
||||
unique_id → HA creates a brand-new sensor, cleanly isolating post-swap data.
|
||||
|
||||
Entity key stability
|
||||
--------------------
|
||||
Entity keys remain the fixed stable strings (``"energy.buy_price_now"`` etc.),
|
||||
**not** derived from the meter uuid. The ``exposed_entity_toggle`` table uses
|
||||
keys as its primary handle; keeping them stable means toggled-on entities stay
|
||||
enabled after a meter swap without requiring the user to re-tick them.
|
||||
|
||||
Current-price algorithm (source-agnostic, with fallback)
|
||||
---------------------------------------------------------
|
||||
@@ -399,8 +428,9 @@ def _energy_cost_provider(session: Session) -> list[ExposableEntity]:
|
||||
Cumulative totals
|
||||
-----------------
|
||||
``SUM(import_cost)`` and ``SUM(export_revenue)`` over **all non-degraded**
|
||||
``energy_cost_period`` rows. Degraded rows carry 0 costs and are excluded
|
||||
to avoid double-counting when they are later overwritten by real values.
|
||||
``energy_cost_period`` rows within the current meter's window. Degraded rows
|
||||
carry 0 costs and are excluded to avoid double-counting when they are later
|
||||
overwritten by real values.
|
||||
|
||||
Currency
|
||||
--------
|
||||
@@ -414,16 +444,37 @@ def _energy_cost_provider(session: Session) -> list[ExposableEntity]:
|
||||
- ``"energy.sell_price_now"``
|
||||
- ``"energy.import_cost_total"``
|
||||
- ``"energy.export_revenue_total"``
|
||||
- ``"energy.import_cost_today"``
|
||||
- ``"energy.export_revenue_today"``
|
||||
|
||||
DeviceInfo identifiers
|
||||
----------------------
|
||||
**Two-element tuple** ``("energy-cost", "energy-cost")`` so that
|
||||
``ha_discovery.py``'s ``entity.device.identifiers[1]`` is always valid
|
||||
(the service uses index [1] as the node_id throughout).
|
||||
**Two-element tuple** ``("energy-cost", meter.uuid)`` so that
|
||||
``ha_discovery.py``'s ``entity.device.identifiers[1]`` resolves to the
|
||||
meter uuid (used as the MQTT node_id and unique_id seed throughout).
|
||||
"""
|
||||
from app.models.energy import EnergyCostPeriod # local import to avoid circular
|
||||
from app.models.energy import EnergyCostPeriod, Meter # local import to avoid circular
|
||||
from sqlalchemy import select
|
||||
|
||||
# --- Determine currency and representative pricing from the latest non-degraded row ---
|
||||
# --- Require an active electricity meter; return [] if none exists ---
|
||||
# Using an inline query (ended_at IS NULL) rather than a service-layer helper
|
||||
# to avoid a new public dependency and remain consistent with the value_getter
|
||||
# implementations below (which use the same inline pattern).
|
||||
active_meter: Meter | None = session.execute(
|
||||
select(Meter)
|
||||
.where(
|
||||
Meter.commodity == "electricity",
|
||||
Meter.ended_at.is_(None),
|
||||
)
|
||||
.limit(1)
|
||||
).scalar_one_or_none()
|
||||
|
||||
if active_meter is None:
|
||||
# No active electricity meter → do not expose any energy-cost entities.
|
||||
# HA will not see these sensors until a meter is declared.
|
||||
return []
|
||||
|
||||
# --- Determine currency from the latest non-degraded row ---
|
||||
|
||||
latest_period: EnergyCostPeriod | None = (
|
||||
session.query(EnergyCostPeriod)
|
||||
@@ -436,13 +487,15 @@ def _energy_cost_provider(session: Session) -> list[ExposableEntity]:
|
||||
if latest_period is not None and latest_period.currency:
|
||||
currency = latest_period.currency
|
||||
|
||||
# --- Shared DeviceInfo (2-element identifiers — required by ha_discovery.py [1] access) ---
|
||||
# --- Shared DeviceInfo anchored to the active meter's uuid ---
|
||||
# identifiers[1] = meter.uuid drives the MQTT node_id and unique_id in
|
||||
# ha_discovery.py. Swapping the meter produces a new uuid → new HA sensor.
|
||||
# provides_availability=False: the energy-cost device has only sensors and no
|
||||
# online/offline heartbeat, so its entities must be "always available" in HA.
|
||||
# (Otherwise HA shows them unavailable despite state being published.)
|
||||
device_info = DeviceInfo(
|
||||
identifiers=("energy-cost", "energy-cost"),
|
||||
name="Energy Cost",
|
||||
identifiers=("energy-cost", active_meter.uuid),
|
||||
name=active_meter.label,
|
||||
provides_availability=False,
|
||||
)
|
||||
|
||||
@@ -687,7 +740,11 @@ def _energy_cost_provider(session: Session) -> list[ExposableEntity]:
|
||||
return None
|
||||
|
||||
# Today's window in UTC, using monkeypatch-safe module attribute calls.
|
||||
today_local = _tz_mod.local_now().date()
|
||||
# Grace: subtract _TODAY_RESET_GRACE so that in the first 5 seconds after
|
||||
# local midnight the getter still returns yesterday's window. This prevents
|
||||
# a "归零后的值" from being published while HA's clock (which may lag a few
|
||||
# seconds) would stamp it as 23:59:59 of the previous day.
|
||||
today_local = (_tz_mod.local_now() - _TODAY_RESET_GRACE).date()
|
||||
tomorrow_local = today_local + _td(days=1)
|
||||
today_start_utc = _tz_mod.local_midnight_utc(today_local)
|
||||
tomorrow_start_utc = _tz_mod.local_midnight_utc(tomorrow_local)
|
||||
@@ -724,7 +781,8 @@ def _energy_cost_provider(session: Session) -> list[ExposableEntity]:
|
||||
if not versions:
|
||||
return None
|
||||
|
||||
today_local = _tz_mod.local_now().date()
|
||||
# Grace: same logic as import_cost_today — see that getter's comment.
|
||||
today_local = (_tz_mod.local_now() - _TODAY_RESET_GRACE).date()
|
||||
tomorrow_local = today_local + _td(days=1)
|
||||
today_start_utc = _tz_mod.local_midnight_utc(today_local)
|
||||
tomorrow_start_utc = _tz_mod.local_midnight_utc(tomorrow_local)
|
||||
|
||||
@@ -1,8 +1,11 @@
|
||||
"""Modbus TCP driver — thin wrapper around pymodbus.
|
||||
|
||||
This module provides a single public function ``read_blocks`` that performs
|
||||
one or more FC04 (Read Input Registers) block reads against a Modbus TCP
|
||||
gateway and returns a flat ``dict[register_address -> 16-bit_value]`` map.
|
||||
one or more block reads against a Modbus TCP gateway — using either FC04
|
||||
(Read Input Registers) or FC03 (Read Holding Registers), selected per call
|
||||
via the ``function_code`` argument — and returns a flat
|
||||
``dict[register_address -> 16-bit_value]`` map. The function code comes from
|
||||
the device profile (e.g. SDM120 uses FC04, DDSU666 uses FC03).
|
||||
|
||||
Design decisions
|
||||
----------------
|
||||
@@ -80,9 +83,10 @@ def read_blocks(
|
||||
unit_id: int,
|
||||
blocks: Sequence[Block],
|
||||
*,
|
||||
function_code: int = 4,
|
||||
timeout: float = 3.0,
|
||||
) -> dict[int, int]:
|
||||
"""Read one or more contiguous register blocks via FC04 (input registers).
|
||||
"""Read one or more contiguous register blocks via FC03 or FC04.
|
||||
|
||||
Parameters
|
||||
----------
|
||||
@@ -96,6 +100,11 @@ def read_blocks(
|
||||
Sequence of ``{"start": int, "count": int}`` dicts describing the
|
||||
contiguous register ranges to read. ``count`` is the number of
|
||||
16-bit registers (not bytes).
|
||||
function_code:
|
||||
Modbus read function code: ``4`` for FC04 (Read Input Registers,
|
||||
default — SDM120) or ``3`` for FC03 (Read Holding Registers —
|
||||
DDSU666 and other devices that expose measurements as holding
|
||||
registers). Comes from the device profile's ``function_code`` field.
|
||||
timeout:
|
||||
TCP connect/read timeout in seconds (default 3 s).
|
||||
|
||||
@@ -107,12 +116,21 @@ def read_blocks(
|
||||
|
||||
Raises
|
||||
------
|
||||
ModbusDriverError
|
||||
If ``function_code`` is neither 3 nor 4 (validated before any
|
||||
connection is attempted).
|
||||
ModbusConnectionError
|
||||
If the TCP connection to the gateway fails.
|
||||
ModbusResponseError
|
||||
If the gateway returns a Modbus exception frame or an unexpected
|
||||
number of registers.
|
||||
"""
|
||||
if function_code not in (3, 4):
|
||||
raise ModbusDriverError(
|
||||
f"Unsupported read function code FC{function_code:02d} "
|
||||
f"(only FC03 holding-register and FC04 input-register reads are supported)"
|
||||
)
|
||||
|
||||
client = ModbusTcpClient(host, port=port, timeout=timeout)
|
||||
try:
|
||||
connected = client.connect()
|
||||
@@ -125,7 +143,7 @@ def read_blocks(
|
||||
for block in blocks:
|
||||
start: int = block["start"]
|
||||
count: int = block["count"]
|
||||
_read_block(client, unit_id, start, count, registers)
|
||||
_read_block(client, unit_id, start, count, registers, function_code=function_code)
|
||||
|
||||
return registers
|
||||
|
||||
@@ -145,9 +163,18 @@ def _read_block(
|
||||
start: int,
|
||||
count: int,
|
||||
result: dict[int, int],
|
||||
*,
|
||||
function_code: int,
|
||||
) -> None:
|
||||
"""Read one block and merge into *result*. Raises on any error."""
|
||||
"""Read one block and merge into *result*. Raises on any error.
|
||||
|
||||
``function_code`` is assumed already validated to be 3 or 4 by the caller
|
||||
(``read_blocks``); 3 dispatches FC03 (holding) and 4 dispatches FC04 (input).
|
||||
"""
|
||||
try:
|
||||
if function_code == 3:
|
||||
response = client.read_holding_registers(start, count=count, device_id=unit_id)
|
||||
else: # function_code == 4 (input registers)
|
||||
response = client.read_input_registers(start, count=count, device_id=unit_id)
|
||||
except ConnectionException as exc:
|
||||
raise ModbusConnectionError(
|
||||
|
||||
@@ -0,0 +1,82 @@
|
||||
name: ddsu666
|
||||
description: CHINT DDSU666 single-phase smart meter
|
||||
function_code: 3 # holding registers (FC03) — DDSU666 has NO input registers (no FC04)
|
||||
word_order: big # high register first — ASSUMED; verify with a known voltage reading
|
||||
byte_order: big # high byte first within each register (confirmed by manual CRC example)
|
||||
|
||||
# NOTE: the manual gives no worked float-decode example, so word_order is a best-guess
|
||||
# (standard big-endian, high register first, matching sdm120). After wiring the meter,
|
||||
# read 0x2000 (voltage) — it should decode to ~230 V. If it decodes to garbage, the
|
||||
# device uses the opposite word order and this profile (and the decoder) need adjusting.
|
||||
# Byte order is confirmed big-endian from the manual (Appendix A, Table A.4: 0x1388 -> 13 88).
|
||||
|
||||
blocks:
|
||||
# Instantaneous quantities 0x2000–0x200F: voltage, current, P, Q, (rsv), PF, (rsv), Freq.
|
||||
# 16 contiguous registers — single bulk read. (DDSU666 manual Table 9.)
|
||||
- { start: 0x2000, count: 0x0010 }
|
||||
# Active energy — import (0x4000) and export (0x400A) read as two small blocks rather
|
||||
# than one span, to avoid touching the undocumented/reserved 0x4002–0x4009 gap.
|
||||
- { start: 0x4000, count: 0x0002 }
|
||||
- { start: 0x400A, count: 0x0002 }
|
||||
|
||||
metrics:
|
||||
# Addresses are the raw Modbus protocol addresses (hex) from DDSU666 manual Table 9,
|
||||
# read via FC03. Each float32 occupies two consecutive 16-bit registers.
|
||||
|
||||
- key: voltage
|
||||
address: 0x2000 # U — Voltage (V)
|
||||
type: float32
|
||||
unit: "V"
|
||||
device_class: voltage
|
||||
ha_component: sensor
|
||||
|
||||
- key: current
|
||||
address: 0x2002 # I — Current (A)
|
||||
type: float32
|
||||
unit: "A"
|
||||
device_class: current
|
||||
ha_component: sensor
|
||||
|
||||
- key: active_power
|
||||
address: 0x2004 # P — Active power. Manual unit is kW (NOT W like sdm120).
|
||||
type: float32
|
||||
unit: "kW"
|
||||
device_class: power
|
||||
ha_component: sensor
|
||||
|
||||
- key: reactive_power
|
||||
address: 0x2006 # Q — Reactive power (kvar)
|
||||
type: float32
|
||||
unit: "kvar"
|
||||
device_class: reactive_power
|
||||
ha_component: sensor
|
||||
|
||||
- key: power_factor
|
||||
address: 0x200A # PF — Power factor (dimensionless)
|
||||
type: float32
|
||||
unit: ""
|
||||
device_class: power_factor
|
||||
ha_component: sensor
|
||||
|
||||
- key: frequency
|
||||
address: 0x200E # Freq — Frequency (Hz)
|
||||
type: float32
|
||||
unit: "Hz"
|
||||
device_class: frequency
|
||||
ha_component: sensor
|
||||
|
||||
- key: import_energy
|
||||
address: 0x4000 # Ep — positive/forward active energy (kWh)
|
||||
type: float32
|
||||
unit: "kWh"
|
||||
device_class: energy
|
||||
state_class: total_increasing
|
||||
ha_component: sensor
|
||||
|
||||
- key: export_energy
|
||||
address: 0x400A # -Ep — reverse active energy (kWh)
|
||||
type: float32
|
||||
unit: "kWh"
|
||||
device_class: energy
|
||||
state_class: total_increasing
|
||||
ha_component: sensor
|
||||
+27
@@ -7,6 +7,7 @@ from fastapi import FastAPI, HTTPException, Request
|
||||
from fastapi.responses import FileResponse
|
||||
from fastapi.staticfiles import StaticFiles
|
||||
from apscheduler.schedulers.background import BackgroundScheduler
|
||||
from apscheduler.triggers.cron import CronTrigger
|
||||
from apscheduler.triggers.interval import IntervalTrigger
|
||||
from sqlalchemy.orm import Session
|
||||
|
||||
@@ -36,6 +37,7 @@ from app.services.modbus_poll import poll_all_enabled_devices, BASE_POLL_TICK_SE
|
||||
from app.services.ha_discovery import publish_discovery, publish_states
|
||||
from app.services.tibber_prices import refresh_prices
|
||||
from app.services.energy_cost import compute_closed_periods
|
||||
from app.services.timezone import local_tz
|
||||
from scripts.app_db_adopt import AppDatabaseAdoptionError, validate_app_runtime_db
|
||||
|
||||
logger = logging.getLogger(__name__)
|
||||
@@ -159,6 +161,20 @@ def _run_scheduled_ha_state_publish() -> None:
|
||||
session.close()
|
||||
|
||||
|
||||
def _run_midnight_state_publish() -> None:
|
||||
"""本地午夜后不久专门发布一次状态,让 *_today 的每日归零稳稳落在午夜之后
|
||||
(对 HA 钟慢几秒鲁棒)。best-effort:失败仅记日志,不影响调度器。"""
|
||||
session_local = get_session_local()
|
||||
session = session_local()
|
||||
try:
|
||||
from app.services.ha_discovery import publish_states
|
||||
publish_states(session)
|
||||
except Exception:
|
||||
logger.exception("_run_midnight_state_publish: failed (non-fatal)")
|
||||
finally:
|
||||
session.close()
|
||||
|
||||
|
||||
def ensure_auth_db_ready() -> None:
|
||||
session_local = get_session_local()
|
||||
session: Session = session_local()
|
||||
@@ -233,6 +249,17 @@ async def lifespan(_: FastAPI):
|
||||
max_instances=1,
|
||||
coalesce=True,
|
||||
)
|
||||
# Dedicated midnight publish: fire at local 00:00:10 so *_today grace (5 s) has
|
||||
# already elapsed and the day-rolled value is pushed to HA immediately, rather
|
||||
# than waiting for the next 60-second ha-state-publish sweep.
|
||||
scheduler.add_job(
|
||||
_run_midnight_state_publish,
|
||||
trigger=CronTrigger(hour=0, minute=0, second=10, timezone=local_tz()),
|
||||
id="midnight-today-publish",
|
||||
replace_existing=True,
|
||||
max_instances=1,
|
||||
coalesce=True,
|
||||
)
|
||||
scheduler.start()
|
||||
|
||||
# MQTT: connect using DB-merged runtime settings so broker configured via UI
|
||||
|
||||
@@ -11,6 +11,7 @@ Six tables:
|
||||
|
||||
from __future__ import annotations
|
||||
|
||||
import uuid as _uuid
|
||||
from datetime import datetime
|
||||
|
||||
from sqlalchemy import Boolean, DateTime, Float, ForeignKey, Integer, String
|
||||
@@ -20,6 +21,10 @@ from sqlalchemy.types import JSON
|
||||
from app.db import Base
|
||||
|
||||
|
||||
def _uuid4_str() -> str:
|
||||
return str(_uuid.uuid4())
|
||||
|
||||
|
||||
class Meter(Base):
|
||||
"""One physical electricity meter's installation epoch.
|
||||
|
||||
@@ -47,6 +52,11 @@ class Meter(Base):
|
||||
|
||||
id: Mapped[int] = mapped_column(Integer, primary_key=True, autoincrement=True)
|
||||
|
||||
# Stable internal identity — used as HA Discovery unique_id anchor.
|
||||
uuid: Mapped[str] = mapped_column(
|
||||
String(36), unique=True, nullable=False, default=_uuid4_str
|
||||
)
|
||||
|
||||
# Human-readable label for this physical meter (e.g. address, serial, tariff zone).
|
||||
label: Mapped[str] = mapped_column(String(255), nullable=False)
|
||||
|
||||
|
||||
+73
-26
@@ -123,6 +123,10 @@ _READING_MAX_STALENESS = timedelta(minutes=_PERIOD_MINUTES)
|
||||
# degraded to prevent negative costs or grossly inflated charges.
|
||||
_MAX_DELTA_KWH = Decimal("100")
|
||||
|
||||
# 每日固定费/税补在"本地午夜后多久"才结算入账。延后到 01:05 是为了让累计成本的
|
||||
# 整天阶跃落在新一天、且避开 01:00 整点(HA 长期统计的小时桶边界)。
|
||||
_SETTLEMENT_OFFSET = timedelta(hours=1, minutes=5)
|
||||
|
||||
# DSMR payload register keys (cumulative kWh, JSON string values).
|
||||
_KEY_D1 = "electricity_delivered_1" # delivered low-tariff (dal / _1)
|
||||
_KEY_D2 = "electricity_delivered_2" # delivered high-tariff (normal / _2)
|
||||
@@ -678,15 +682,33 @@ def summarize(session: Session, start: datetime, end: datetime) -> dict[str, Any
|
||||
+ fixed_costs -- per-day standing charges, cross-version
|
||||
- credits -- per-day heffingskorting, cross-version
|
||||
|
||||
**Fixed-cost / credit counting — Principle C**:
|
||||
Only *already-elapsed* whole local calendar days are counted. For each
|
||||
local calendar date D in the window ``[start_local_date, min(end_local_date,
|
||||
tomorrow_local))``, the contract version whose rate covers D (the one whose
|
||||
effective_from local-date ≤ D < next version's effective_from local-date) is
|
||||
used. Days that have not yet started in local time (D > today_local) are
|
||||
never counted. This is cross-version: if the active contract has V1 from
|
||||
June 1 and V2 from June 25, querying June 1–30 uses V1 for days 1-24 and V2
|
||||
for day 25. Switching versions never resets the counter.
|
||||
**Fixed-cost / credit counting — Principle C (symmetric begin/end)**:
|
||||
Both the local calendar day in which *start* falls and the local calendar
|
||||
day in which *end* falls are counted as full days. Fixed charges
|
||||
(network_fee, management_fee) and the energy-tax credit (heffingskorting)
|
||||
are assessed on a "service-is-active" basis — if the meter was online on a
|
||||
given calendar day, the full day's charge/credit applies, regardless of
|
||||
whether the window starts at midnight or mid-morning.
|
||||
|
||||
For each local calendar date D in the range
|
||||
``[local_date(start), min(local_date(end), today_local)]``:
|
||||
- D ≤ today_local (only elapsed / today days count as "whole days").
|
||||
- The contract version whose effective_from local-date ≤ D is used.
|
||||
- This is cross-version: if V1 is from June 1 and V2 from June 25,
|
||||
querying June 1–30 uses V1 for days 1-24 and V2 for day 25.
|
||||
|
||||
The end-day (last_counted) is included when the end's local midnight falls
|
||||
strictly before end_utc; combined with the always-counted start day this
|
||||
makes the begin/end handling symmetric. A short same-day window therefore
|
||||
counts its single local day. A window contributes 0 days only when the
|
||||
counted range is empty (first_counted > last_counted) — e.g. a window lying
|
||||
entirely in the future, since last_counted is capped at today_local.
|
||||
|
||||
Daily getters (``*_today``) use windows exactly aligned to local midnight,
|
||||
so their ``first_counted`` is always today — unaffected by this fix.
|
||||
|
||||
Days that have not yet started in local time (D > today_local) are
|
||||
never counted. Switching versions never resets the counter.
|
||||
|
||||
**Timezone note**: the ``days`` field in the returned dict still represents
|
||||
the window length in calendar days (total_seconds / 86400), for backward
|
||||
@@ -746,29 +768,46 @@ def summarize(session: Session, start: datetime, end: datetime) -> dict[str, Any
|
||||
days = _to_decimal(str(total_seconds)) / _to_decimal("86400")
|
||||
|
||||
# --- Fixed costs and credits: Principle C cross-version whole-day counting ---
|
||||
today_local: _date = local_now().date()
|
||||
_now_local = local_now()
|
||||
today_local: _date = _now_local.date()
|
||||
|
||||
# --- Compute [first_counted, last_counted] local date range (inclusive) ---
|
||||
#
|
||||
# We count local calendar day D if its LOCAL MIDNIGHT falls within [start_utc, end_utc)
|
||||
# AND D ≤ today_local (only elapsed / today days count as "whole days").
|
||||
# Both the window-start day and the window-end day are counted as complete
|
||||
# local calendar days, regardless of whether the window starts/ends at midnight.
|
||||
#
|
||||
# Semantics: "A day D is counted when its local midnight has arrived (D ≤ today)
|
||||
# AND the local midnight is within the billing window."
|
||||
# Principle C (symmetric begin/end):
|
||||
# • first_counted = local calendar date of start_utc (start day always counted)
|
||||
# • last_counted = local calendar date of end_utc (end day counted if its
|
||||
# local midnight is strictly before end_utc)
|
||||
# • Both are then capped at today_local (only elapsed / today days count).
|
||||
#
|
||||
# This means a sub-day window [10:00, 10:30) UTC that doesn't contain any
|
||||
# local midnight contributes 0 days, while a window [22:00 UTC, 23:00 UTC) that
|
||||
# contains CEST midnight (= 22:00 UTC) contributes 1 day.
|
||||
# Why symmetric? Fixed charges (network_fee, management_fee) and energy-tax credits
|
||||
# (heffingskorting) are assessed on a "service-is-active" basis, not on how many
|
||||
# hours the service was actually running within that calendar day. If the meter
|
||||
# anchor (started_at) falls at 09:18 on June 24, the full June 24 standing charge
|
||||
# and credit still apply because the service was online for that day.
|
||||
#
|
||||
# Implementation: compute the first and last local date whose midnight is in range.
|
||||
# Previous asymmetric behaviour: a start_utc that was *later* than the local
|
||||
# midnight of local_start_date caused first_counted to be bumped to the *next*
|
||||
# day, silently dropping the anchor day's charges/credits. This was incorrect
|
||||
# for cumulative entities (import_cost_total / export_revenue_total) whose anchor
|
||||
# is often an above-midnight started_at. The end-side had always been symmetric
|
||||
# (counted if local midnight < end_utc), creating an inconsistency.
|
||||
#
|
||||
# Daily getters (window = [local today 00:00, local tomorrow 00:00)) are
|
||||
# unaffected: local_date(local_midnight_utc(today)) == today, so first_counted
|
||||
# is still today regardless of the fix.
|
||||
#
|
||||
# A short same-day window now counts its single local day (the start day is
|
||||
# always counted, symmetric with the end side). A window contributes 0 days
|
||||
# only when the counted range is empty (first_counted > last_counted) — e.g. a
|
||||
# window lying entirely in the future, where last_counted is capped at
|
||||
# today_local while first_counted is later.
|
||||
from app.services.timezone import local_midnight_utc as _lmu
|
||||
|
||||
local_start_date: _date = local_date(start_utc)
|
||||
# Is the midnight of local_start_date ≥ start_utc? If not, first midnight is next day.
|
||||
if _lmu(local_start_date) >= start_utc:
|
||||
first_counted: _date = local_start_date
|
||||
else:
|
||||
first_counted = local_start_date + _td(days=1)
|
||||
# Start side: always count the local calendar day in which start_utc falls.
|
||||
first_counted: _date = local_date(start_utc)
|
||||
|
||||
local_end_date: _date = local_date(end_utc)
|
||||
# Is the midnight of local_end_date < end_utc? If yes, that day's midnight is in range.
|
||||
@@ -777,8 +816,16 @@ def summarize(session: Session, start: datetime, end: datetime) -> dict[str, Any
|
||||
else:
|
||||
last_counted = local_end_date - _td(days=1)
|
||||
|
||||
# Cap: only elapsed or today's days.
|
||||
last_counted = min(last_counted, today_local)
|
||||
# Settlement cap: "today" is only counted once the local clock has passed the
|
||||
# settlement offset since midnight (01:05). This defers the daily standing-charge
|
||||
# step from 00:00 to 01:05, ensuring the cumulative-cost adiabatic jump lands
|
||||
# inside the new calendar day and avoids the HA 01:00 hourly-bucket boundary.
|
||||
_today_midnight_utc = _lmu(today_local)
|
||||
if _now_local >= _today_midnight_utc + _SETTLEMENT_OFFSET:
|
||||
settled_cap = today_local
|
||||
else:
|
||||
settled_cap = today_local - _td(days=1)
|
||||
last_counted = min(last_counted, settled_cap)
|
||||
|
||||
# If the range is empty (first_counted > last_counted), no days are counted.
|
||||
|
||||
|
||||
@@ -64,6 +64,7 @@ def poll_device(session: Session, device: ModbusDevice) -> ModbusReading | None:
|
||||
device.port,
|
||||
device.unit_id,
|
||||
[{"start": b.start, "count": b.count} for b in profile.blocks],
|
||||
function_code=profile.function_code,
|
||||
)
|
||||
payload = profiles.decode(profile, registers)
|
||||
|
||||
|
||||
Binary file not shown.
@@ -0,0 +1,198 @@
|
||||
# DDSU666 Modbus 协议(从官方 PDF 提取)
|
||||
|
||||
> 来源:`docs/references/DDSU666 Single phase Smart Meter.pdf`
|
||||
> (CHINT / 正泰仪表 **DDSU666 Single phase Smart Meter — Operation Manual**,文档号 `ZTY0.464.1224`,版本 **V2**,2020 年 8 月;厂商 Zhejiang Chint Instrument & Meter Co., Ltd.)
|
||||
> 本文件是 PDF 的可读化提取,供本项目的 Modbus 采集驱动设计参考。**以官方 PDF 为准**,本文件如有出入以 PDF 为准。
|
||||
> 同类文档见 SDM120 的 `SDM120-Modbus-Protocol.md`;两表差异较大,见下方 §6「与 SDM120 的关键差异」。
|
||||
|
||||
## 设备速览(来自手册 Table 1 / Table 5)
|
||||
|
||||
| 项 | DDSU666(直接接入) | DDSU666-CT(经互感器) |
|
||||
| --- | --- | --- |
|
||||
| 精度等级 | Active Class B | Active Class C |
|
||||
| 参考电压 | 230 V | 230 V |
|
||||
| 电流规格 | 0.25–5(80) A | 0.015–1.5(6) A |
|
||||
| 表常数 | 800 imp/kWh | 6400 imp/kWh |
|
||||
| 接入方式 | 直接接入 | 经电流互感器 |
|
||||
|
||||
- 单相电子式电能表,DIN35mm 导轨安装;测量电压、电流、有功/无功功率、频率、功率因数、正/反向有功电能。
|
||||
- 电能测量范围 `0~999999.99 kWh`(LCD 只显示 6 位,自动移动小数点)。
|
||||
- 通信:RS485,**Modbus-RTU**(也支持 DL/T 645-2007,可切换,见 §5 `0005H ChangeProtocol`)。
|
||||
- 手册 Table 1 标注 Frequency Reference = 60Hz,但 LCD 示例又写 `F=50.00Hz`(手册自身不一致);**实际频率以寄存器 `200EH` 读数为准**,不要把 50/60 写死。
|
||||
|
||||
## 0. 本项目的接入方式(重要)
|
||||
|
||||
DDSU666 物理层是 **Modbus RTU(RS-485 串口)**,半双工。和 SDM120 一样,本项目通过一个 **Modbus-TCP 网关**接入:
|
||||
|
||||
- 后端用 **Modbus TCP**(`IP:port`)连到网关,网关在串口侧转成 RTU 与电表通信。
|
||||
- TCP 帧用 MBAP header、**无 CRC**(CRC 由网关在 RTU 侧处理)。本文档里 RTU 帧的 `CRC (Lo/Hi)` 字段在 TCP 模式下不需要我们关心。
|
||||
- **Slave Address / Unit ID = 电表的通信地址 Addr**(范围 1–247;面板按键只能设 1–99;见 §5 `0006H`),在 TCP 请求里作为 unit id 传入。
|
||||
- 若以后直连串口(RTU),才需要管波特率 / 数据格式 / CRC:**默认串口格式是 8 数据位、无校验、2 停止位(8N2)**,与 SDM120 的 8N1 不同——直连时务必对齐。
|
||||
- 电表必须处于 **Modbus 协议模式**(而非 DL/T 645)才能用本协议;可经面板长按切换,或写 `0005H = 2`(见 §5)。
|
||||
|
||||
## 1. 协议帧格式(Appendix A)
|
||||
|
||||
异步传输,按字节为单位。一帧 10 位字符 = **1 起始位(0) + 8 数据位(无校验) + 2 停止位(1)**(其它格式可定制)。
|
||||
|
||||
### 信息帧结构(Table A.1)
|
||||
|
||||
| 字段 | 长度 | 说明 |
|
||||
| --- | --- | --- |
|
||||
| Start(起始) | >3.5 字符静默 | 帧间至少 3.5 字符空闲时间作为分隔 |
|
||||
| Address code(地址码) | 1 字节 | 目标从机地址 1–247;每个从机在总线上地址唯一 |
|
||||
| Function code(功能码) | 1 字节 | 仅支持 **03H / 10H**(见 §2) |
|
||||
| Data(数据域) | n 字节 | 随功能码不同而不同(起始地址、寄存器数、寄存器数据等) |
|
||||
| CRC check code(CRC 校验) | 2 字节 | 16-bit CRC(**低字节在前、高字节在后**;多项式 `A001`) |
|
||||
| End(结束) | >3.5 字符静默 | 帧间静默 |
|
||||
|
||||
> TCP 网关模式下 Start/End 静默与 CRC 由网关处理,本项目不关心。
|
||||
|
||||
### 功能码 03H 示例(读寄存器,Table A.3/A.4)
|
||||
|
||||
读从机 `01H`、起始地址 `0CH`、2 个寄存器:
|
||||
|
||||
- 主机发送:`01 03 00 0C 00 02 04 08`(最后 `04 08` 是 CRC,低字节 `04` 在前)。
|
||||
- 从机返回(设 `0CH/0DH` 内容为 `0000H`、`1388H`):`01 03 04 00 00 13 88 F7 65`
|
||||
- `04` = 字节数;`00 00` = `0CH` 数据;`13 88` = `0DH` 数据;`F7 65` = CRC(低字节 `F7` 在前)。
|
||||
|
||||
> **注意**:单个 16-bit 寄存器内是「高字节在前、低字节在后」(Table A.4 里 `0DH` 数据返回 `13 88` = `0x1388`)。这一点对解码浮点的字节序很关键,见 §3。
|
||||
|
||||
### 功能码 10H 示例(写多个寄存器,Table A.5/A.6)
|
||||
|
||||
向从机 `01H`、起始地址 `00H` 连续写 3 个寄存器 `0002H,1388H,000AH`:
|
||||
|
||||
- 主机发送:`01 10 00 00 00 03 06 00 02 13 88 00 0A 9B E9`
|
||||
- `06` = 写入字节数(3 寄存器 × 2 字节);随后是 3 个寄存器的数据;末尾 `9B E9` CRC。
|
||||
- 从机返回:`01 10 00 00 00 03 80 08`(回显起始地址 + 寄存器数 + CRC `80 08`)。
|
||||
|
||||
### 异常响应(Table A.7/A.8)
|
||||
|
||||
- 异常时返回的 Function Code = **原功能码 + 128**(即最高位置 1,`03H→83H`、`10H→90H`)。
|
||||
- 数据为单字节 Error Code:
|
||||
|
||||
| Error Code | 含义 | 说明 |
|
||||
| --- | --- | --- |
|
||||
| `01H` | Illegal function code | 收到的功能码本表不支持 |
|
||||
| `02H` | Illegal register address | 寄存器地址超出有效范围 |
|
||||
| `03H` | Illegal data value | 数据值超出对应地址的取值范围 |
|
||||
|
||||
## 2. 功能码
|
||||
|
||||
DDSU666 **只支持两个功能码**(Table A.2):
|
||||
|
||||
| 功能码 | 作用 | 说明 |
|
||||
| --- | --- | --- |
|
||||
| **03H** | Read register(读寄存器) | 读一个或多个寄存器——**测量值、电量、配置全部走它** |
|
||||
| **10H** | Write multiple registers(写多个寄存器) | 向 n 个连续寄存器写 n 个 16-bit 数据(改配置 / 清电量) |
|
||||
|
||||
> ⚠️ **DDSU666 没有「输入寄存器 / FC04」概念**——所有数据(包括电压电流功率)都用 **FC 03H** 读保持寄存器。这是它和 SDM120(测量值走 FC04)最大的踩坑差异,见 §6。
|
||||
|
||||
## 3. 数据编码
|
||||
|
||||
DDSU666 有两类数据:
|
||||
|
||||
1. **配置 / 参数寄存器(§5,`0000H`–`0010H`)**:每个 1 个寄存器、`16-bit with symbols`(**16 位有符号整数**)。
|
||||
2. **测量 / 电量寄存器(§4,`2000H`+ / `4000H`+)**:每个参数 = **32-bit IEEE-754 单精度浮点**(手册写 “single precision floating decimal”),占 **2 个相邻寄存器**(Length = 2 Word)。
|
||||
|
||||
**浮点字节序 / 字序**
|
||||
|
||||
- **字节序(byte order)= 大端:寄存器内高字节在前** —— 由 Table A.4 的 `0x1388` 返回为 `13 88` 确认。
|
||||
- **字序(word order,两个寄存器谁是高 16 位)**:手册**没有给出浮点解码的实例**,未明确标注。按标准 Modbus 浮点惯例应为**大端字序(高寄存器在前,`ABCD`)**,与本项目 SDM120 驱动一致(`registers_to_float` 用 `>f`,高寄存器在前)。
|
||||
- ⚠️ **需上机实测确认**:读 `2000H`(电压)应解出 ~230V 这样的合理值;若解出乱数,多半是字序相反,改成「低寄存器在前」再试。CHINT 同系列(DTSU/DDSU666)现场固件偶有字序差异,**首次接入务必用一个已知量(电压)校验**,不要凭手册想当然。
|
||||
|
||||
> Python 解码(大端、高寄存器在前):`struct.unpack('>f', struct.pack('>HH', hi_reg, lo_reg))[0]`。
|
||||
> pymodbus:`BinaryPayloadDecoder.fromRegisters(regs, byteorder=Endian.BIG, wordorder=Endian.BIG)`。
|
||||
|
||||
## 4. 测量 / 电量寄存器表(FC 03H 读)
|
||||
|
||||
全部为只读、`Float`(32-bit),每项占 **2 个寄存器**。地址为 Modbus 协议原始地址(即帧里的 Start Register Address Hi/Lo),手册用十六进制。
|
||||
|
||||
### 4.1 瞬时量(“Electric quantity of the secondary side”,`2000H` 段)
|
||||
|
||||
| 地址(hex) | 参数 | 代号 | 单位 | 备注 |
|
||||
| --- | --- | --- | --- | --- |
|
||||
| `2000H` | 电压 Voltage | U | V | |
|
||||
| `2002H` | 电流 Current | I | A | |
|
||||
| `2004H` | 有功功率 Active power | P | **kW** | 手册标注 “the unit is KW”——**不是 W** |
|
||||
| `2006H` | 无功功率 Reactive power | Q | **kvar** | |
|
||||
| `2008H` | (保留 RESERVED) | — | — | 占 2 寄存器,跳过 |
|
||||
| `200AH` | 功率因数 Power factor | PF | — | 无量纲 |
|
||||
| `200CH` | (保留 RESERVED) | — | — | 占 2 寄存器,跳过 |
|
||||
| `200EH` | 频率 Frequency | Freq | Hz | |
|
||||
|
||||
### 4.2 电量(“Electrical data of the secondary side”,`4000H` 段)
|
||||
|
||||
| 地址(hex) | 参数 | 代号 | 单位 | 备注 |
|
||||
| --- | --- | --- | --- | --- |
|
||||
| `4000H` | 正向(导入)有功电能 Active in electricity | Ep | kWh | 正向 / forward active energy |
|
||||
| `400AH` | 反向(导出)有功电能 Reverse in electricity | -Ep | kWh | 反向 / reverse active energy |
|
||||
|
||||
> 手册里 `4000H` 与 `400AH` 之间(`4002H`–`4009H`)未列出,视为保留/未文档化。
|
||||
|
||||
**读取分块建议**
|
||||
|
||||
- 瞬时量:`2000H`–`200FH` 共 **16 个寄存器连续**,一次块读即可覆盖 U…Freq(含两段 RESERVED,解码时跳过)。
|
||||
- 电量:`4000H`(2 寄存器)与 `400AH`(2 寄存器)相距较远,分两小块读,或读 `4000H`–`400BH`(12 寄存器)一次取出后挑用——以网关 / 电表是否允许跨保留地址块读为准,谨慎起见分开读更稳。
|
||||
|
||||
### 常用核心子集(日常监控够用)
|
||||
|
||||
电压 `2000H`、电流 `2002H`、有功功率 `2004H`(kW)、功率因数 `200AH`、频率 `200EH`、正向有功电能 `4000H`、反向有功电能 `400AH`。
|
||||
|
||||
## 5. 配置 / 参数寄存器表(FC 03H 读 / FC 10H 写)(Table 9)
|
||||
|
||||
每个 1 个寄存器、**16-bit 有符号整数**。`R/W` 列来自手册。
|
||||
|
||||
| 地址(hex) | 代号 | 含义 | R/W | 取值 / 说明 |
|
||||
| --- | --- | --- | --- | --- |
|
||||
| `0000H` | UCode | 编程密码 Programming password code | R/W | 写配置前的密码字 |
|
||||
| `0001H` | REV. | 保留;**实际读出的是版本号** | R | |
|
||||
| `0002H` | ClrE | 电能清零 CLr.E | R/W | **写 `1` 清除总电量**(不可逆,慎用) |
|
||||
| `0003H`–`0004H` | RESERVED | 保留 | — | |
|
||||
| `0005H` | ChangeProtocol | 协议切换 | R/W | **`2` = Modbus-RTU**,`1` = DL/T 645-2007 |
|
||||
| `0006H` | Addr | 通信地址 | R/W | 1–247(面板按键仅 1–99) |
|
||||
| `0007H`–`000AH` | RESERVED | 保留 | — | |
|
||||
| `000BH` | Meter type | 表型 Meter type | R | 只读设备类型标识 |
|
||||
| `000CH` | BAud | 通信波特率 | R/W | **`1`=2400bps,`2`=4800bps,`3`=9600bps**(手册寄存器仅列这三档;通信章另提到也支持 1200bps) |
|
||||
| `000DH`–`0010H` | RESERVED | 保留 | — | |
|
||||
|
||||
> ⚠️ 写 `0002H`(清电量)、`0006H`(改地址)、`000CH`(改波特率)、`0005H`(切协议)都会改变电表状态或通信参数,配错可能**清空累计电量**或**导致通信中断**。本项目默认**只读采集**,不在自动化链路里写电表配置寄存器。
|
||||
> 写配置通常需先经 `0000H UCode` 密码字校验;具体密码值手册正文未给出,需向厂商确认或经面板操作。
|
||||
|
||||
## 6. 与 SDM120 的关键差异(迁移 / 复用驱动时必看)
|
||||
|
||||
本项目已有 SDM120 profile(`app/integrations/modbus/profiles/sdm120.yaml`)。DDSU666 **不能照搬**,主要差异:
|
||||
|
||||
| 维度 | SDM120 (Eastron) | DDSU666 (CHINT) |
|
||||
| --- | --- | --- |
|
||||
| 读测量值功能码 | **FC 04**(输入寄存器 3X) | **FC 03**(保持寄存器,无 FC04) |
|
||||
| 测量值起始地址 | `0x0000` 起(30001) | 瞬时量 `0x2000` 起;电量 `0x4000`/`0x400A` |
|
||||
| 有功功率单位 | **W**(瓦) | **kW(千瓦)** —— 入库前注意换算 / 单位标注 |
|
||||
| 无功功率单位 | VAr | kvar |
|
||||
| 配置寄存器格式 | Float(FC03/16) | **16-bit 有符号整数**(FC03/10) |
|
||||
| 写功能码 | 16 / 0x10 | 10H(同 0x10) |
|
||||
| 串口默认格式 | 8N1(1 停止位) | **8N2(2 停止位)** |
|
||||
| 多协议 | 仅 Modbus | Modbus **与 DL/T 645-2007 可切换**(需确保在 Modbus 模式) |
|
||||
| 浮点字序 | 大端、高寄存器在前(手册有实例佐证) | 字节序大端已确认;**字序手册无实例,需上机实测** |
|
||||
|
||||
## 7. 给本项目采集驱动的要点小结
|
||||
|
||||
1. 走 **Modbus TCP 网关**:`ModbusTcpClient(host, port)`,`slave=<Addr>`;电表须在 **Modbus 协议模式**。
|
||||
2. 所有读取(测量 + 电量 + 配置)都用 **FC 03H**——**没有 FC04**。
|
||||
3. 测量值在 `0x2000` 段、电量在 `0x4000`/`0x400A`,均为 **float32**;解码大端字节序,**字序默认高寄存器在前但务必用电压实测校验**。
|
||||
4. **有功功率单位是 kW、无功是 kvar**——与 SDM120 的 W/VAr 不同,新建 profile / 入库映射时单位别抄错。
|
||||
5. 配置寄存器(`0x0000`–`0x0010`)是 **16-bit 有符号整数**,不是 float。
|
||||
6. 默认**只读**;`0002H` 写 1 会**清空累计电量**、`0006H/000CH/0005H` 会改通信参数,自动化链路里一律不写。
|
||||
7. 新建 profile 时这是 `ddsu666` 这一个 register profile 的定义;建议 `function_code: 3`、`word_order: big`(先按大端字序,接入后用电压读数验证)、瞬时量与电量分块读。
|
||||
|
||||
## 8. 实测记录(真机验证,2026-06-30)
|
||||
|
||||
首次接入一台 **DDSU666 直接接入版(5(80)A)** 实测,确认以下几点:
|
||||
|
||||
- **字序大端,确认无误**:电压 / 电流 / 频率 / 电能用「大端、高寄存器在前」解码全部得到合理值(如 233.9 V / 0.055 A / 49.99 Hz),与 §3 的假设一致。`ddsu666.yaml` 的 `word_order: big` / `byte_order: big` **无需修改**,§3 里「字序需上机实测」一项可视为已关闭。
|
||||
- **FC03 读通**:所有量走 FC03,profile `ddsu666` 在采集链路(CLI `read` / 设备 `/test` / 后台轮询)中工作正常。
|
||||
- **低电流下「瞬时功率读 0、但电能照常累加」**:测试负载仅为一台 PoE 交换机(≈230 V / 0.05 A,真实有功仅几瓦),**远低于本表测量量程下限 Imin≈0.25 A**。此工况下:
|
||||
- 瞬时 `active_power`(`0x2004`)与 `power_factor`(`0x200A`)寄存器返回**全零**(原始 hex `0x0000 0x0000`);电表 LCD 上功率在 0~3.3 W、PF 在 0~0.6 之间抖动。
|
||||
- 抖动成因 = **低电流测量噪声 + 开关电源(SMPS,无 PFC)畸变电流**(电流为电压峰值附近的窄脉冲、谐波重 → 畸变功率因数天然偏低)。**不是**「采样率与开关频率拍频」:计量芯片 SH79F7019 采样在 kHz 量级,远低于开关电源 50–200 kHz 的开关频率,两者不在一个频段。
|
||||
- 但累计电能 `import_energy`(`0x4000`)**正常累加**(实测 0 → 0.01 kWh)——电表内部积分器在防潜动起始电流(`0.004·Ib`≈0.02 A)之上照常计量。
|
||||
- **结论**:低于量程下限时**瞬时功率 / PF 不可信,但电能计量不丢**;电流进入量程(正常负载)后瞬时量即稳定可信。这是 5(80)A 大量程表对极小负载的固有特性,**非缺陷、非解码问题**。
|
||||
- **排错提示**:若日后看到 DDSU666「功率一直 0」,先确认负载电流是否在 Imin 以上——多半是负载太轻而非链路故障;可用 `scripts/modbus_cli probe --fc 3 --address 0x2000 --count 16` 看 `0x2004/0x2005` 原始寄存器是否真为全零佐证。
|
||||
+26
-1
@@ -288,11 +288,36 @@ httpx / paho-mqtt / pyyaml / apscheduler 均为 M5 已有依赖,M6 复用,
|
||||
|
||||
**动机**:浏览器端走 session cookie 即可,但**脚本 / 设备 / 外部程序调用 API** 需要一种长期有效、可随身携带的凭据。在设置页加一组功能,由 admin **手动签发 long-lived token**,之后用它来调 API。
|
||||
|
||||
**本次明确的首要目标 = 给现在裸奔的 ingestion 端点上鉴权**(2026-06-27 与用户确认):
|
||||
|
||||
- `POST /location/record`(`app/api/routes/location.py:18`)——位置记录上报。**目前无任何鉴权**。当前数据经 Home Assistant 转发进来,上 token 后 **HA 侧需携带该 token**;也可由其他客户端直接上报。
|
||||
- `POST /poo/record`(`app/api/routes/poo.py:21`)+ `GET /poo/latest`(`poo.py:57`)——小狗排便记录上报 / 最新查询。**目前无任何鉴权**。
|
||||
- 这些是设备 / 脚本(非浏览器)端点,session cookie 不适用,正是 long-lived token 的用武之地。(浏览器 CRUD `/api/data/*` 已由 session 保护,不在此列。)
|
||||
|
||||
**范围(粗略,待细化)**:
|
||||
|
||||
- 设置页新增「API Token」区:生成 / 命名 / 吊销 long-lived token;明文只在**生成时展示一次**,此后只存哈希。
|
||||
- 后端支持用该 token 鉴权访问 API(与现有 session cookie 并存,互不影响)。
|
||||
- 后端支持用该 token 鉴权访问 API(与现有 session cookie 并存,互不影响);给上述 ingestion 端点加 token 鉴权依赖。
|
||||
- 与 [M3](#m3--开放与移动端远期试水) 的 token 主题相关,但**这条是 Web 设置页手动签发的 PAT 风格**,不依赖移动端 OAuth 流程;两者实现时可复用同一套 token 存储 / 校验。
|
||||
- 与下面第 3 条「Session 滑动续期」同属 Authentication 主题(一个是设备/脚本的长期凭据,一个是浏览器短会话体验),实现时鉴权层可一并梳理。
|
||||
|
||||
### 3. Session 滑动自动续期(Authentication)
|
||||
|
||||
**动机**(2026-06-27 与用户确认):当前 session 是**绝对过期**——登录即定死、活动不续期,满 TTL 必须重新登录,体验割裂。希望改成**滑动续期(sliding / rolling)**:只要用户还在活动就自动延长,提供"在用就不掉线"的体验。
|
||||
|
||||
**现状(实现起点,便于快速拾起)**:
|
||||
|
||||
- TTL 默认 **12 小时**:`auth_session_ttl_hours`(`app/config.py:38`;配置页 `app/services/config_page.py:45` 可运行时改)。
|
||||
- 登录时**一次性写死**:`create_session` 设 `expires_at = now + ttl`(`app/services/auth.py:94`)+ cookie `max_age = ttl`(`app/api/routes/api/session.py:153`)。
|
||||
- 每请求**只读校验、从不延长**:`get_authenticated_session`(`app/services/auth.py:103`)只判断 `expires_at <= now`,过期时仅顺手标 `revoked`。`set_cookie` 只在登录路由调用一次,**无 per-request 中间件**。→ 所以是绝对过期,不是滑动。
|
||||
|
||||
**设计要点(待写设计文档时展开)**:
|
||||
|
||||
- 校验通过时 bump `expires_at = now + ttl` 并**重发 cookie**(滑动窗口)。
|
||||
- **写节流**:不要每个请求都写 DB——仅当剩余寿命已过半(或距上次续期 > N 分钟)才续期,避免高频写放大。
|
||||
- **绝对寿命硬顶**:除滑动 TTL 外再设 `created_at + max_lifetime` 上限,防止"永不过期"的会话(安全考量)。
|
||||
- 新增配置项:滑动 TTL、绝对寿命上限、续期节流阈值。
|
||||
- 注意:改动只对**新逻辑生效**,已存在 session 的 `expires_at` 行为按新校验路径走即可;上线前过校验闸门。
|
||||
|
||||
## Future Ideas(暂不排期,想到先记下)
|
||||
|
||||
|
||||
Vendored
+4
-3
@@ -591,9 +591,10 @@ export interface paths {
|
||||
*
|
||||
* **Retroactive recompute**: if ``started_at`` is in the past, billing
|
||||
* records from that point forward are re-judged via ``recompute_range`` to
|
||||
* reflect the new meter attribution. The response includes the count of
|
||||
* recomputed periods in ``recomputed_periods`` (not part of ``MeterResponse``
|
||||
* — the recompute is transparent; callers should re-fetch costs if needed).
|
||||
* reflect the new meter attribution. The recompute is transparent — the
|
||||
* response body is the created meter (``MeterResponse``) only and does **not**
|
||||
* include a recompute count; callers should re-fetch costs if they need the
|
||||
* updated totals.
|
||||
*/
|
||||
post: operations["declare_energy_meter_api_energy_meters_post"];
|
||||
delete?: never;
|
||||
|
||||
@@ -258,6 +258,95 @@ describe('MeterManager — declare new meter', () => {
|
||||
})
|
||||
})
|
||||
|
||||
describe('MeterManager — edit meter date initialisation', () => {
|
||||
beforeEach(() => vi.clearAllMocks())
|
||||
|
||||
it('initialises date input from started_at (Z-suffix, UTC midnight → local date)', async () => {
|
||||
// ACTIVE_METER.started_at = '2024-01-15T00:00:00Z' (UTC midnight).
|
||||
// The test suite is pinned to TZ=UTC (via vite.config.ts test.env), so
|
||||
// the local date is deterministically '2024-01-15' on any CI runner.
|
||||
const user = userEvent.setup()
|
||||
mockGet.mockResolvedValue({ data: { items: [ACTIVE_METER], total: 1 } })
|
||||
|
||||
renderWithProviders(<MeterManager />)
|
||||
|
||||
await waitFor(() => expect(screen.getByTestId(`meter-edit-${ACTIVE_METER.id}`)).toBeInTheDocument())
|
||||
await user.click(screen.getByTestId(`meter-edit-${ACTIVE_METER.id}`))
|
||||
await waitFor(() => expect(screen.getByTestId('edit-meter-form')).toBeInTheDocument())
|
||||
|
||||
const dateInput = screen.getByTestId('edit-meter-started-at') as HTMLInputElement
|
||||
expect(dateInput.value).toBe('2024-01-15')
|
||||
})
|
||||
|
||||
it('initialises date input from started_at (naive, no tz marker)', async () => {
|
||||
// A naive timestamp without timezone marker — parseBackendTimestamp appends 'Z'
|
||||
// so it is treated as UTC. With TZ=UTC (pinned in vite.config.ts), the local date
|
||||
// equals the UTC date exactly.
|
||||
const naiveMeter = { ...ACTIVE_METER, started_at: '2024-03-20T00:00:00' }
|
||||
const user = userEvent.setup()
|
||||
mockGet.mockResolvedValue({ data: { items: [naiveMeter], total: 1 } })
|
||||
|
||||
renderWithProviders(<MeterManager />)
|
||||
|
||||
await waitFor(() => expect(screen.getByTestId(`meter-edit-${naiveMeter.id}`)).toBeInTheDocument())
|
||||
await user.click(screen.getByTestId(`meter-edit-${naiveMeter.id}`))
|
||||
await waitFor(() => expect(screen.getByTestId('edit-meter-form')).toBeInTheDocument())
|
||||
|
||||
const dateInput = screen.getByTestId('edit-meter-started-at') as HTMLInputElement
|
||||
expect(dateInput.value).toBe('2024-03-20')
|
||||
})
|
||||
|
||||
it('initialises date input from started_at with explicit UTC offset (+02:00) — regression for old buggy regex', async () => {
|
||||
// The old hand-written regex /[zZ+-]\d*$/ would fail to match '+02:00' (the ':00'
|
||||
// suffix broke the pattern) and would incorrectly append 'Z', producing an Invalid Date.
|
||||
// The new code uses parseBackendTimestamp which uses the correct TZ_MARKER_RE regex
|
||||
// and handles explicit offsets properly.
|
||||
const offsetMeter = { ...ACTIVE_METER, started_at: '2024-01-15T02:00:00+02:00' }
|
||||
// UTC equivalent: 2024-01-15T00:00:00Z → with TZ=UTC (pinned) local date = '2024-01-15'
|
||||
const user = userEvent.setup()
|
||||
mockGet.mockResolvedValue({ data: { items: [offsetMeter], total: 1 } })
|
||||
|
||||
renderWithProviders(<MeterManager />)
|
||||
|
||||
await waitFor(() => expect(screen.getByTestId(`meter-edit-${offsetMeter.id}`)).toBeInTheDocument())
|
||||
await user.click(screen.getByTestId(`meter-edit-${offsetMeter.id}`))
|
||||
await waitFor(() => expect(screen.getByTestId('edit-meter-form')).toBeInTheDocument())
|
||||
|
||||
const dateInput = screen.getByTestId('edit-meter-started-at') as HTMLInputElement
|
||||
// Must not be empty (which would indicate Invalid Date from the old buggy path)
|
||||
expect(dateInput.value).not.toBe('')
|
||||
expect(dateInput.value).toBe('2024-01-15')
|
||||
})
|
||||
|
||||
it('does not include started_at in PATCH body when date is unchanged (round-trip idempotence)', async () => {
|
||||
// Open the edit form and immediately submit without changing any fields except label.
|
||||
// The date should be considered unchanged → no started_at in the PATCH body.
|
||||
const user = userEvent.setup()
|
||||
mockGet.mockResolvedValue({ data: { items: [ACTIVE_METER], total: 1 } })
|
||||
mockPatch.mockResolvedValue({ data: { ...ACTIVE_METER, label: 'New label' } })
|
||||
|
||||
renderWithProviders(<MeterManager />)
|
||||
|
||||
await waitFor(() => expect(screen.getByTestId(`meter-edit-${ACTIVE_METER.id}`)).toBeInTheDocument())
|
||||
await user.click(screen.getByTestId(`meter-edit-${ACTIVE_METER.id}`))
|
||||
await waitFor(() => expect(screen.getByTestId('edit-meter-form')).toBeInTheDocument())
|
||||
|
||||
// Change only label; leave date untouched
|
||||
const labelInput = screen.getByTestId('edit-meter-label')
|
||||
await user.clear(labelInput)
|
||||
await user.type(labelInput, 'New label')
|
||||
|
||||
await user.click(screen.getByTestId('edit-meter-submit'))
|
||||
|
||||
await waitFor(() => {
|
||||
expect(mockPatch).toHaveBeenCalled()
|
||||
})
|
||||
|
||||
const patchBody = mockPatch.mock.calls[0][1].body
|
||||
expect(patchBody).not.toHaveProperty('started_at')
|
||||
})
|
||||
})
|
||||
|
||||
describe('MeterManager — edit meter', () => {
|
||||
beforeEach(() => vi.clearAllMocks())
|
||||
|
||||
|
||||
@@ -38,7 +38,7 @@ import {
|
||||
type MeterReason,
|
||||
} from './hooks'
|
||||
import { ApiError } from '../api/client'
|
||||
import { formatLocalDate } from '../utils/datetime'
|
||||
import { formatLocalDate, parseBackendTimestamp } from '../utils/datetime'
|
||||
|
||||
// ---------------------------------------------------------------------------
|
||||
// Helpers
|
||||
@@ -60,6 +60,19 @@ function toLocalMidnightNaive(dateStr: string): string {
|
||||
return `${dateStr}T00:00:00`
|
||||
}
|
||||
|
||||
/**
|
||||
* Format a Date object as a "YYYY-MM-DD" string using the browser's local timezone.
|
||||
* Used to populate <input type="date"> fields.
|
||||
* Returns '' if the Date is invalid.
|
||||
*/
|
||||
function toLocalDateInputString(d: Date): string {
|
||||
if (isNaN(d.getTime())) return ''
|
||||
const y = d.getFullYear()
|
||||
const m = String(d.getMonth() + 1).padStart(2, '0')
|
||||
const day = String(d.getDate()).padStart(2, '0')
|
||||
return `${y}-${m}-${day}`
|
||||
}
|
||||
|
||||
// ---------------------------------------------------------------------------
|
||||
// Declare meter form (modal)
|
||||
// ---------------------------------------------------------------------------
|
||||
@@ -204,19 +217,12 @@ interface EditMeterFormProps {
|
||||
function EditMeterForm({ meter, onClose, onSaved }: EditMeterFormProps) {
|
||||
const [label, setLabel] = useState(meter.label)
|
||||
const [note, setNote] = useState(meter.note ?? '')
|
||||
// Convert UTC started_at to a local date string for the <input type="date">.
|
||||
// We parse as UTC (appending Z if needed) and format to "YYYY-MM-DD" in local tz.
|
||||
const initialDateStr = (() => {
|
||||
const iso = meter.started_at.includes('T') && !meter.started_at.match(/[zZ+-]\d*$/)
|
||||
? meter.started_at + 'Z'
|
||||
: meter.started_at
|
||||
const d = new Date(iso)
|
||||
if (isNaN(d.getTime())) return ''
|
||||
const y = d.getFullYear()
|
||||
const m = String(d.getMonth() + 1).padStart(2, '0')
|
||||
const day = String(d.getDate()).padStart(2, '0')
|
||||
return `${y}-${m}-${day}`
|
||||
})()
|
||||
// Convert started_at to a local date string for the <input type="date">.
|
||||
// parseBackendTimestamp correctly handles naive strings (no tz marker → treated as UTC,
|
||||
// matching the backend's storage convention), Z-suffixed strings, and strings with
|
||||
// explicit offsets like +02:00. We then extract the local-timezone date components
|
||||
// so the displayed date matches the local wall-clock date of the meter start.
|
||||
const initialDateStr = toLocalDateInputString(parseBackendTimestamp(meter.started_at))
|
||||
const [dateStr, setDateStr] = useState(initialDateStr)
|
||||
const [error, setError] = useState<string | null>(null)
|
||||
|
||||
|
||||
@@ -20,5 +20,13 @@ export default defineConfig({
|
||||
environment: 'jsdom',
|
||||
globals: true,
|
||||
setupFiles: ['./src/test-setup.ts'],
|
||||
env: {
|
||||
// Lock the test timezone to UTC so that date-formatting assertions
|
||||
// (which rely on toLocalDateInputString / getFullYear etc.) produce
|
||||
// deterministic results regardless of the CI runner's local timezone.
|
||||
// All fixture timestamps are UTC midnight, so the expected YYYY-MM-DD
|
||||
// values in MeterManager.test.tsx are correct under UTC.
|
||||
TZ: 'UTC',
|
||||
},
|
||||
},
|
||||
})
|
||||
|
||||
@@ -1405,7 +1405,7 @@
|
||||
"api-energy-meters"
|
||||
],
|
||||
"summary": "Declare Energy Meter",
|
||||
"description": "Declare a new meter epoch (swap, home move, or initial declaration).\n\nCloses the current active meter for the given commodity at ``started_at``\nand opens a new active meter. If no active meter exists, the new meter is\nsimply created without closing anything.\n\n**Validation**: ``started_at`` must be **≥** the current active meter's\nown ``started_at`` (no chronological backdate below the active epoch's\nstart). Equal timestamps are allowed (replaces the current meter at the\nsame logical moment). Violation → 422.\n\n**Retroactive recompute**: if ``started_at`` is in the past, billing\nrecords from that point forward are re-judged via ``recompute_range`` to\nreflect the new meter attribution. The response includes the count of\nrecomputed periods in ``recomputed_periods`` (not part of ``MeterResponse``\n— the recompute is transparent; callers should re-fetch costs if needed).",
|
||||
"description": "Declare a new meter epoch (swap, home move, or initial declaration).\n\nCloses the current active meter for the given commodity at ``started_at``\nand opens a new active meter. If no active meter exists, the new meter is\nsimply created without closing anything.\n\n**Validation**: ``started_at`` must be **≥** the current active meter's\nown ``started_at`` (no chronological backdate below the active epoch's\nstart). Equal timestamps are allowed (replaces the current meter at the\nsame logical moment). Violation → 422.\n\n**Retroactive recompute**: if ``started_at`` is in the past, billing\nrecords from that point forward are re-judged via ``recompute_range`` to\nreflect the new meter attribution. The recompute is transparent — the\nresponse body is the created meter (``MeterResponse``) only and does **not**\ninclude a recompute count; callers should re-fetch costs if they need the\nupdated totals.",
|
||||
"operationId": "declare_energy_meter_api_energy_meters_post",
|
||||
"parameters": [
|
||||
{
|
||||
|
||||
@@ -1125,11 +1125,13 @@ paths:
|
||||
|
||||
records from that point forward are re-judged via ``recompute_range`` to
|
||||
|
||||
reflect the new meter attribution. The response includes the count of
|
||||
reflect the new meter attribution. The recompute is transparent — the
|
||||
|
||||
recomputed periods in ``recomputed_periods`` (not part of ``MeterResponse``
|
||||
response body is the created meter (``MeterResponse``) only and does **not**
|
||||
|
||||
— the recompute is transparent; callers should re-fetch costs if needed).'
|
||||
include a recompute count; callers should re-fetch costs if they need the
|
||||
|
||||
updated totals.'
|
||||
operationId: declare_energy_meter_api_energy_meters_post
|
||||
parameters:
|
||||
- name: X-CSRF-Token
|
||||
|
||||
@@ -15,7 +15,7 @@ if str(PROJECT_ROOT) not in sys.path:
|
||||
|
||||
from app.config import get_settings
|
||||
|
||||
APP_BASELINE_REVISION = "20260625_13_meter_table"
|
||||
APP_BASELINE_REVISION = "20260625_14_meter_uuid"
|
||||
|
||||
|
||||
class AppDatabaseAdoptionError(RuntimeError):
|
||||
|
||||
@@ -131,6 +131,7 @@ def cmd_read(args: argparse.Namespace) -> None:
|
||||
|
||||
print(f"Profile : {profile.name} — {profile.description}")
|
||||
print(f"Gateway : {host}:{port} unit_id={unit_id}")
|
||||
print(f"Function : FC{profile.function_code:02d}")
|
||||
print(f"Blocks : {[(b.start, b.count) for b in profile.blocks]}")
|
||||
print()
|
||||
|
||||
@@ -141,7 +142,7 @@ def cmd_read(args: argparse.Namespace) -> None:
|
||||
from app.integrations.modbus.driver import read_blocks
|
||||
|
||||
try:
|
||||
registers = read_blocks(host, port, unit_id, blocks)
|
||||
registers = read_blocks(host, port, unit_id, blocks, function_code=profile.function_code)
|
||||
except ModbusConnectionError as exc:
|
||||
print(f"Connection error: {exc}", file=sys.stderr)
|
||||
sys.exit(1)
|
||||
|
||||
@@ -72,6 +72,24 @@ def _declare_payload(**overrides) -> dict:
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
|
||||
@pytest.fixture(autouse=True)
|
||||
def mock_publish_discovery():
|
||||
"""Auto-mock publish_discovery for all tests in this module.
|
||||
|
||||
The meters API now calls _trigger_discovery_republish (best-effort) after
|
||||
every successful write. publish_discovery is lazy-imported inside that
|
||||
helper, so we patch it at its canonical source path
|
||||
(app.services.ha_discovery.publish_discovery). Tests that need to assert
|
||||
the call receive this fixture explicitly; all others benefit from the
|
||||
isolation it provides (no live MQTT broker required).
|
||||
"""
|
||||
with patch(
|
||||
"app.services.ha_discovery.publish_discovery",
|
||||
return_value=None,
|
||||
) as mock:
|
||||
yield mock
|
||||
|
||||
|
||||
@pytest.fixture()
|
||||
def meters_client(auth_database):
|
||||
"""TestClient + SQLAlchemy engine for Meter API tests."""
|
||||
@@ -543,7 +561,7 @@ def test_patch_meter_no_recompute_when_started_at_not_changed(meters_client):
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Timeline continuity (integration: no recompute mock)
|
||||
# Timeline continuity (recompute mocked to avoid slow computation over empty quarters)
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
|
||||
@@ -615,7 +633,7 @@ def test_declare_meter_invalid_reason_returns_422(meters_client):
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Retroactive recompute: integration (no mock) — window coverage check
|
||||
# Retroactive recompute & boundary update (recompute mocked) — window coverage check
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
|
||||
@@ -660,3 +678,78 @@ def test_patch_started_at_earlier_updates_boundary(meters_client):
|
||||
if ended is not None and ended.tzinfo is None:
|
||||
ended = ended.replace(tzinfo=UTC)
|
||||
assert ended == t1_earlier
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# FUE-T06: HA discovery re-publish triggered after meter writes
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
|
||||
def test_declare_meter_triggers_publish_discovery(meters_client, mock_publish_discovery):
|
||||
"""POST /api/energy/meters triggers publish_discovery after successful commit."""
|
||||
client, _ = meters_client
|
||||
_login(client)
|
||||
|
||||
t0 = datetime(2025, 1, 1, 0, 0, 0, tzinfo=UTC)
|
||||
with patch("app.api.routes.api.meters.recompute_range", return_value=0):
|
||||
resp = client.post(
|
||||
"/api/energy/meters",
|
||||
json=_declare_payload(label="Discovery Meter", started_at=t0.isoformat()),
|
||||
headers={"X-CSRF-Token": _CSRF},
|
||||
)
|
||||
assert resp.status_code == 201
|
||||
# publish_discovery must have been called exactly once after the declare.
|
||||
mock_publish_discovery.assert_called_once()
|
||||
|
||||
|
||||
def test_patch_meter_triggers_publish_discovery(meters_client, mock_publish_discovery):
|
||||
"""PATCH /api/energy/meters/{id} triggers publish_discovery after successful commit."""
|
||||
client, _ = meters_client
|
||||
_login(client)
|
||||
|
||||
t0 = datetime(2025, 1, 1, 0, 0, 0, tzinfo=UTC)
|
||||
with patch("app.api.routes.api.meters.recompute_range", return_value=0):
|
||||
resp = client.post(
|
||||
"/api/energy/meters",
|
||||
json=_declare_payload(label="Original Label", started_at=t0.isoformat()),
|
||||
headers={"X-CSRF-Token": _CSRF},
|
||||
)
|
||||
meter_id = resp.json()["id"]
|
||||
# Reset call count: the POST above also called publish_discovery.
|
||||
mock_publish_discovery.reset_mock()
|
||||
|
||||
resp = client.patch(
|
||||
f"/api/energy/meters/{meter_id}",
|
||||
json={"label": "Renamed Label"},
|
||||
headers={"X-CSRF-Token": _CSRF},
|
||||
)
|
||||
assert resp.status_code == 200
|
||||
# publish_discovery must have been called exactly once after the PATCH.
|
||||
mock_publish_discovery.assert_called_once()
|
||||
|
||||
|
||||
def test_declare_meter_succeeds_when_publish_discovery_raises(meters_client):
|
||||
"""publish_discovery raising an exception must NOT cause POST declare to return 500.
|
||||
|
||||
The _trigger_discovery_republish helper is best-effort: it swallows all
|
||||
exceptions so that a broken MQTT / discovery layer never breaks the API.
|
||||
"""
|
||||
client, _ = meters_client
|
||||
_login(client)
|
||||
|
||||
t0 = datetime(2025, 1, 1, 0, 0, 0, tzinfo=UTC)
|
||||
with (
|
||||
patch("app.api.routes.api.meters.recompute_range", return_value=0),
|
||||
patch(
|
||||
"app.services.ha_discovery.publish_discovery",
|
||||
side_effect=RuntimeError("MQTT broker unreachable"),
|
||||
),
|
||||
):
|
||||
resp = client.post(
|
||||
"/api/energy/meters",
|
||||
json=_declare_payload(label="Best Effort Meter", started_at=t0.isoformat()),
|
||||
headers={"X-CSRF-Token": _CSRF},
|
||||
)
|
||||
# The meter must be created successfully despite the discovery failure.
|
||||
assert resp.status_code == 201
|
||||
assert resp.json()["label"] == "Best Effort Meter"
|
||||
|
||||
+485
-38
@@ -996,35 +996,52 @@ class TestSummarize:
|
||||
assert result["period_count"] == 2
|
||||
assert result["degraded_count"] == 0
|
||||
|
||||
def test_fixed_costs_zero_for_sub_day_window(self, energy_db: Session) -> None:
|
||||
"""Principle C: a 30-minute window within the same local day counts 0 whole days.
|
||||
def test_fixed_costs_one_day_for_sub_day_window(self, energy_db: Session) -> None:
|
||||
"""FUE-T01 (symmetric begin/end): a 30-minute window within one local day counts 1 day.
|
||||
|
||||
Fixed costs are only added for elapsed whole local calendar days.
|
||||
A window [10:00, 10:30) UTC stays within the same local calendar date
|
||||
regardless of timezone offset (any UTC-11..UTC+14 range), so no whole
|
||||
day is covered → fixed_costs = 0.
|
||||
Under the symmetric-begin/end fix, fixed charges are assessed on a
|
||||
"service-is-active" basis: if the window falls within a local calendar day,
|
||||
that entire day's charge applies. The begin side no longer requires a local
|
||||
midnight to fall *inside* the window — the local date of start_utc itself is
|
||||
always counted as the first day.
|
||||
|
||||
Window [10:00, 10:30) UTC in Europe/Amsterdam (CEST = UTC+2):
|
||||
local date of start: June 23 (12:00 CEST)
|
||||
local date of end: June 23 (12:30 CEST)
|
||||
→ first_counted = last_counted = June 23 → 1 day
|
||||
→ fixed_costs = (9.87 + 9.87) / 30 × 1
|
||||
"""
|
||||
from zoneinfo import ZoneInfo
|
||||
from unittest.mock import patch
|
||||
|
||||
self._setup_two_periods(energy_db)
|
||||
# Pin the local timezone so the test is deterministic on any CI host.
|
||||
with __import__("unittest.mock", fromlist=["patch"]).patch.object(
|
||||
tz_module, "local_tz", return_value=ZoneInfo("Europe/Amsterdam")
|
||||
):
|
||||
with patch.object(tz_module, "local_tz", return_value=ZoneInfo("Europe/Amsterdam")):
|
||||
result = summarize(energy_db, _ts(10, 0), _ts(10, 30))
|
||||
assert result["fixed_costs"] == 0.0, (
|
||||
"Sub-day window should contribute 0 whole-day fixed costs under Principle C"
|
||||
|
||||
expected_fixed = (9.87 + 9.87) / 30 # 1 day
|
||||
assert abs(result["fixed_costs"] - expected_fixed) < 1e-9, (
|
||||
f"FUE-T01: sub-day window in one local day should count 1 day of fixed costs; "
|
||||
f"expected {expected_fixed:.6f}, got {result['fixed_costs']}"
|
||||
)
|
||||
|
||||
def test_credits_zero_for_sub_day_window(self, energy_db: Session) -> None:
|
||||
"""Principle C: a 30-minute window within the same local day counts 0 whole days for credits."""
|
||||
def test_credits_one_day_for_sub_day_window(self, energy_db: Session) -> None:
|
||||
"""FUE-T01 (symmetric begin/end): a 30-minute window within one local day counts 1 day of credits.
|
||||
|
||||
Same rationale as test_fixed_costs_one_day_for_sub_day_window.
|
||||
credits = 600.0 / 365 × 1 day.
|
||||
"""
|
||||
from zoneinfo import ZoneInfo
|
||||
from unittest.mock import patch
|
||||
|
||||
self._setup_two_periods(energy_db)
|
||||
with __import__("unittest.mock", fromlist=["patch"]).patch.object(
|
||||
tz_module, "local_tz", return_value=ZoneInfo("Europe/Amsterdam")
|
||||
):
|
||||
with patch.object(tz_module, "local_tz", return_value=ZoneInfo("Europe/Amsterdam")):
|
||||
result = summarize(energy_db, _ts(10, 0), _ts(10, 30))
|
||||
assert result["credits"] == 0.0, (
|
||||
"Sub-day window should contribute 0 whole-day credits under Principle C"
|
||||
|
||||
expected_credits = 600.0 / 365 # 1 day
|
||||
assert abs(result["credits"] - expected_credits) < 1e-9, (
|
||||
f"FUE-T01: sub-day window in one local day should count 1 day of credits; "
|
||||
f"expected {expected_credits:.6f}, got {result['credits']}"
|
||||
)
|
||||
|
||||
def test_total_payable_formula(self, energy_db: Session) -> None:
|
||||
@@ -1068,12 +1085,20 @@ class TestSummarize:
|
||||
assert result["period_count"] == 0
|
||||
|
||||
def test_one_day_summarize_hand_calc(self, energy_db: Session) -> None:
|
||||
"""Full 1-day hand-calculation: fixed_costs/30 and credits/365 with 1-day interval.
|
||||
"""Full 1-day hand-calculation: fixed_costs/30 and credits/365 with 1-day UTC interval.
|
||||
|
||||
Principle C: the window [2026-06-23 00:00 UTC, 2026-06-24 00:00 UTC) spans
|
||||
exactly one local calendar day in Europe/Amsterdam (CEST=UTC+2: 02:00→02:00).
|
||||
effective_from = June 23 00:00 UTC = June 23 02:00 CEST = local date June 23.
|
||||
Today (2026-06-25) ≥ June 23, so the day is elapsed → 1 day counted.
|
||||
FUE-T01 (symmetric begin/end): the window [2026-06-23 00:00 UTC, 2026-06-24 00:00 UTC)
|
||||
in Europe/Amsterdam (CEST=UTC+2):
|
||||
- local date of start (June 23 00:00 UTC = June 23 02:00 CEST) = June 23
|
||||
→ first_counted = June 23 (anchor day always counted)
|
||||
- local midnight of June 24 = June 23 22:00 UTC, which is < end_utc (June 24 00:00 UTC)
|
||||
→ last_counted = June 24
|
||||
- today (2026-06-25) ≥ June 24 → cap doesn't apply
|
||||
→ 2 local calendar days counted (June 23 + June 24)
|
||||
|
||||
Note: a 1-day UTC window centered at non-midnight UTC spans **two** local days
|
||||
in Amsterdam (CEST=UTC+2) because local midnight (June 23 22:00 UTC) falls
|
||||
inside the window. This is correct under the symmetric begin/end principle.
|
||||
"""
|
||||
from zoneinfo import ZoneInfo
|
||||
from unittest.mock import patch
|
||||
@@ -1091,12 +1116,18 @@ class TestSummarize:
|
||||
with patch.object(tz_module, "local_tz", return_value=ZoneInfo("Europe/Amsterdam")):
|
||||
result = summarize(energy_db, start, end)
|
||||
|
||||
# fixed_costs = (9.87 + 9.87) / 30 × 1.0 = 0.658
|
||||
assert abs(result["fixed_costs"] - (9.87 + 9.87) / 30) < 1e-9
|
||||
# credits = 600 / 365
|
||||
assert abs(result["credits"] - 600.0 / 365) < 1e-9
|
||||
# total = 0 + 0.658 − (600/365)
|
||||
expected_total = (9.87 + 9.87) / 30 - 600.0 / 365
|
||||
# 2 local days (June 23 start day + June 24 because local midnight of June 24
|
||||
# = June 23 22:00 UTC falls within [start, end)).
|
||||
n_days = 2
|
||||
assert abs(result["fixed_costs"] - (9.87 + 9.87) / 30 * n_days) < 1e-9, (
|
||||
f"FUE-T01: 1-day UTC window = 2 local days in Amsterdam; "
|
||||
f"expected fixed={((9.87 + 9.87) / 30 * n_days):.6f}, got {result['fixed_costs']}"
|
||||
)
|
||||
assert abs(result["credits"] - 600.0 / 365 * n_days) < 1e-9, (
|
||||
f"FUE-T01: expected credits={600.0 / 365 * n_days:.6f}, got {result['credits']}"
|
||||
)
|
||||
# total = 0 + fixed − credits
|
||||
expected_total = (9.87 + 9.87) / 30 * n_days - 600.0 / 365 * n_days
|
||||
assert abs(result["total_payable"] - expected_total) < 1e-9
|
||||
|
||||
|
||||
@@ -1168,10 +1199,16 @@ def _ams_midnight(year: int, month: int, day: int) -> datetime:
|
||||
|
||||
|
||||
class TestSummarizePrincipleC:
|
||||
"""Principle C whole-day counting with pinned Europe/Amsterdam timezone."""
|
||||
"""Principle C whole-day counting with pinned Europe/Amsterdam timezone.
|
||||
|
||||
Tests that assert a specific "today" (e.g. June 25) must also pin
|
||||
``local_now`` via *pinned_now* to remain deterministic as wall-clock
|
||||
time advances. Tests that only care about windows entirely in the past
|
||||
or entirely in the future do not need to pin ``local_now``.
|
||||
"""
|
||||
|
||||
# Effective_from: June 1 CEST local midnight = May 31 22:00 UTC.
|
||||
# Today local = June 25 CEST (since today is 2026-06-25).
|
||||
# Reference "today" pinned in individual tests = June 25 CEST.
|
||||
|
||||
def _make_single_version_contract(self, session: Session, *, effective_from_utc: datetime) -> None:
|
||||
"""Create an active manual contract with a single version."""
|
||||
@@ -1179,10 +1216,27 @@ class TestSummarizePrincipleC:
|
||||
_make_version(session, contract, _MANUAL_VALUES, effective_from=effective_from_utc)
|
||||
session.commit()
|
||||
|
||||
def _run_summarize_ams(self, session: Session, start_utc: datetime, end_utc: datetime) -> dict:
|
||||
"""Run summarize with Europe/Amsterdam local_tz monkeypatched."""
|
||||
def _run_summarize_ams(
|
||||
self,
|
||||
session: Session,
|
||||
start_utc: datetime,
|
||||
end_utc: datetime,
|
||||
*,
|
||||
pinned_now: datetime | None = None,
|
||||
) -> dict:
|
||||
"""Run summarize with Europe/Amsterdam local_tz monkeypatched.
|
||||
|
||||
If *pinned_now* is given, also patches ``app.services.energy_cost.local_now``
|
||||
to that fixed value, making settlement-offset logic deterministic
|
||||
regardless of wall-clock time.
|
||||
"""
|
||||
from unittest.mock import patch
|
||||
import app.services.energy_cost as _ec
|
||||
|
||||
with patch.object(tz_module, "local_tz", return_value=_ams()):
|
||||
if pinned_now is not None:
|
||||
with patch.object(_ec, "local_now", return_value=pinned_now):
|
||||
return summarize(session, start_utc, end_utc)
|
||||
return summarize(session, start_utc, end_utc)
|
||||
|
||||
def test_today_window_counts_1_day(self, energy_db: Session) -> None:
|
||||
@@ -1228,7 +1282,10 @@ class TestSummarizePrincipleC:
|
||||
def test_this_month_window_counts_25_days(self, energy_db: Session) -> None:
|
||||
"""This Month (June 1 → July 1 local) counts 25 elapsed days (June 1..25).
|
||||
|
||||
Today = June 25 local, so June 26–30 are not yet elapsed.
|
||||
Pins ``local_now`` to June 25 noon AMS so the test is deterministic
|
||||
regardless of the actual wall-clock date. June 25 is well past the
|
||||
01:05 settlement offset, so ``settled_cap = June 25``.
|
||||
Today = June 25 local, so June 26–30 are not yet elapsed → 25 days.
|
||||
Matches table row: 6/1→7/1 (This Month) → 25 days.
|
||||
"""
|
||||
eff_utc = _ams_midnight(2026, 6, 1)
|
||||
@@ -1236,7 +1293,9 @@ class TestSummarizePrincipleC:
|
||||
|
||||
start = _ams_midnight(2026, 6, 1)
|
||||
end = _ams_midnight(2026, 7, 1)
|
||||
result = self._run_summarize_ams(energy_db, start, end)
|
||||
# Pin local_now to June 25 2026 noon AMS (well past 01:05 settlement).
|
||||
pinned_now = datetime(2026, 6, 25, 12, 0, 0, tzinfo=_ams())
|
||||
result = self._run_summarize_ams(energy_db, start, end, pinned_now=pinned_now)
|
||||
|
||||
daily_fixed = (9.87 + 9.87) / 30
|
||||
daily_credit = 600.0 / 365
|
||||
@@ -1273,8 +1332,9 @@ class TestSummarizePrincipleC:
|
||||
def test_partial_future_window_caps_at_today(self, energy_db: Session) -> None:
|
||||
"""A window partially in the future caps at today (only elapsed days counted).
|
||||
|
||||
Pins ``local_now`` to June 25 noon AMS so the test is deterministic.
|
||||
Window: June 25 → June 28 local (4 dates, but June 26/27 are future).
|
||||
Today = June 25 → only 1 day elapsed (June 25).
|
||||
Today = June 25 → settled_cap = June 25 → only 1 day elapsed (June 25).
|
||||
Matches table row: 6/25→6/28 → 1 day.
|
||||
"""
|
||||
eff_utc = _ams_midnight(2026, 6, 1)
|
||||
@@ -1282,7 +1342,9 @@ class TestSummarizePrincipleC:
|
||||
|
||||
start = _ams_midnight(2026, 6, 25)
|
||||
end = _ams_midnight(2026, 6, 28)
|
||||
result = self._run_summarize_ams(energy_db, start, end)
|
||||
# Pin local_now to June 25 2026 noon AMS (well past 01:05 settlement).
|
||||
pinned_now = datetime(2026, 6, 25, 12, 0, 0, tzinfo=_ams())
|
||||
result = self._run_summarize_ams(energy_db, start, end, pinned_now=pinned_now)
|
||||
|
||||
daily_fixed = (9.87 + 9.87) / 30
|
||||
daily_credit = 600.0 / 365
|
||||
@@ -1335,7 +1397,11 @@ class TestSummarizePrincipleC:
|
||||
start = _ams_midnight(2026, 6, 1)
|
||||
end = _ams_midnight(2026, 7, 1)
|
||||
from unittest.mock import patch
|
||||
import app.services.energy_cost as _ec
|
||||
# Pin local_now to June 25 2026 noon AMS: today=June 25, settled_cap=June 25.
|
||||
pinned_now = datetime(2026, 6, 25, 12, 0, 0, tzinfo=_ams())
|
||||
with patch.object(tz_module, "local_tz", return_value=_ams()):
|
||||
with patch.object(_ec, "local_now", return_value=pinned_now):
|
||||
result = summarize(energy_db, start, end)
|
||||
|
||||
# V1: 24 days × (6+6)/30; V2: 1 day × (12+12)/30
|
||||
@@ -1377,11 +1443,15 @@ class TestSummarizePrincipleC:
|
||||
_make_version(energy_db, contract, _VALUES_V2, effective_from=v2_from)
|
||||
energy_db.commit()
|
||||
|
||||
# Window = June 25 only (today, 1 day elapsed at V2 rate)
|
||||
# Window = June 25 only (today, 1 day elapsed at V2 rate).
|
||||
# Pin local_now to June 25 noon AMS: today=June 25, settled_cap=June 25.
|
||||
start = _ams_midnight(2026, 6, 25)
|
||||
end = _ams_midnight(2026, 7, 1)
|
||||
from unittest.mock import patch
|
||||
import app.services.energy_cost as _ec
|
||||
pinned_now = datetime(2026, 6, 25, 12, 0, 0, tzinfo=_ams())
|
||||
with patch.object(tz_module, "local_tz", return_value=_ams()):
|
||||
with patch.object(_ec, "local_now", return_value=pinned_now):
|
||||
result = summarize(energy_db, start, end)
|
||||
|
||||
# Only 1 day at V2 rate
|
||||
@@ -1390,6 +1460,120 @@ class TestSummarizePrincipleC:
|
||||
assert abs(result["fixed_costs"] - expected_fixed) < 1e-9
|
||||
assert abs(result["credits"] - expected_credits) < 1e-9
|
||||
|
||||
def test_morning_anchor_first_day_counted(self, energy_db: Session) -> None:
|
||||
"""FUE-T01: anchor falling above local midnight counts its local day as day 1.
|
||||
|
||||
Bug scenario: meter.started_at = June 24 09:18 local time (07:18 UTC, CEST=UTC+2).
|
||||
Old code: local_date(07:18 UTC) = June 24; _lmu(June 24) = June 23 22:00 UTC;
|
||||
June 23 22:00 UTC < June 24 07:18 UTC → False (22:00 < 07:18? No — 22:00 UTC June 23 is
|
||||
*before* 07:18 UTC June 24; so the condition >= start_utc was False);
|
||||
first_counted bumped to June 25. June 24's charges were silently dropped.
|
||||
|
||||
Fix: first_counted = local_date(start_utc) = June 24 always, regardless of where
|
||||
within the day start_utc falls. June 24 is the anchor day → its charge is counted.
|
||||
|
||||
Window: [June 24 07:18 UTC (= 09:18 CEST), June 26 22:00 UTC (= June 27 00:00 CEST)).
|
||||
Pins local_now to June 25 noon AMS → today=June 25, settled_cap=June 25.
|
||||
first_counted = June 24 (anchor day, previously dropped).
|
||||
last_counted = min(June 26, June 25) = June 25.
|
||||
n_days = June 25 - June 24 + 1 = 2.
|
||||
"""
|
||||
eff_utc = _ams_midnight(2026, 6, 1)
|
||||
self._make_single_version_contract(energy_db, effective_from_utc=eff_utc)
|
||||
|
||||
# anchor = June 24 07:18 UTC = June 24 09:18 CEST (above local midnight)
|
||||
anchor_utc = datetime(2026, 6, 24, 7, 18, 0, tzinfo=_UTC)
|
||||
# end = June 26 22:00 UTC = June 27 00:00 CEST (past today June 25, capped)
|
||||
end_utc = datetime(2026, 6, 26, 22, 0, 0, tzinfo=_UTC)
|
||||
|
||||
# Pin local_now to June 25 noon AMS: today=June 25, settled_cap=June 25.
|
||||
pinned_now = datetime(2026, 6, 25, 12, 0, 0, tzinfo=_ams())
|
||||
result = self._run_summarize_ams(energy_db, anchor_utc, end_utc, pinned_now=pinned_now)
|
||||
|
||||
daily_fixed = (9.87 + 9.87) / 30
|
||||
daily_credit = 600.0 / 365
|
||||
# June 24 (anchor day) + June 25 (today) = 2 days
|
||||
assert abs(result["fixed_costs"] - daily_fixed * 2) < 1e-9, (
|
||||
f"FUE-T01: morning anchor should count anchor day + today = 2 days of fixed costs; "
|
||||
f"expected {daily_fixed * 2:.6f}, got {result['fixed_costs']}"
|
||||
)
|
||||
assert abs(result["credits"] - daily_credit * 2) < 1e-9, (
|
||||
f"FUE-T01: morning anchor should count anchor day + today = 2 days of credits; "
|
||||
f"expected {daily_credit * 2:.6f}, got {result['credits']}"
|
||||
)
|
||||
|
||||
def test_daily_window_midnight_aligned_unaffected(self, energy_db: Session) -> None:
|
||||
"""FUE-T01: the daily getter window [today midnight, tomorrow midnight) is not affected.
|
||||
|
||||
The *_today getters use windows exactly aligned to local midnight:
|
||||
start = local_midnight_utc(today) = June 24 22:00 UTC (for June 25 local)
|
||||
end = local_midnight_utc(tomorrow) = June 25 22:00 UTC
|
||||
|
||||
With either old or new logic, first_counted = June 25 (today):
|
||||
- Old: local_date(June 24 22:00 UTC in Amsterdam) = June 25;
|
||||
_lmu(June 25) = June 24 22:00 UTC >= June 24 22:00 UTC → True → first = June 25.
|
||||
- New: first_counted = local_date(June 24 22:00 UTC) = June 25.
|
||||
Both give the same result: 1 day counted.
|
||||
|
||||
This test explicitly verifies daily window behaviour is unchanged.
|
||||
"""
|
||||
from unittest.mock import patch
|
||||
|
||||
eff_utc = _ams_midnight(2026, 6, 1)
|
||||
self._make_single_version_contract(energy_db, effective_from_utc=eff_utc)
|
||||
|
||||
# Today's window aligned to local midnight (June 25 CEST = June 24 22:00 UTC).
|
||||
today_start_utc = _ams_midnight(2026, 6, 25) # June 24 22:00 UTC
|
||||
tomorrow_start_utc = _ams_midnight(2026, 6, 26) # June 25 22:00 UTC
|
||||
|
||||
with patch.object(tz_module, "local_tz", return_value=_ams()):
|
||||
result = self._run_summarize_ams(energy_db, today_start_utc, tomorrow_start_utc)
|
||||
|
||||
daily_fixed = (9.87 + 9.87) / 30
|
||||
daily_credit = 600.0 / 365
|
||||
# Exactly 1 day counted (June 25 only; June 26 is future, capped).
|
||||
assert abs(result["fixed_costs"] - daily_fixed * 1) < 1e-9, (
|
||||
f"FUE-T01: daily window should count exactly 1 day; "
|
||||
f"expected {daily_fixed:.6f}, got {result['fixed_costs']}"
|
||||
)
|
||||
assert abs(result["credits"] - daily_credit * 1) < 1e-9, (
|
||||
f"FUE-T01: daily window should count exactly 1 day of credits; "
|
||||
f"expected {daily_credit:.6f}, got {result['credits']}"
|
||||
)
|
||||
|
||||
def test_single_day_morning_anchor_counts_one_day(self, energy_db: Session) -> None:
|
||||
"""FUE-T01: a window starting mid-morning on a single local day counts that 1 day.
|
||||
|
||||
Window: [June 24 08:00 UTC (= 10:00 CEST), June 24 22:00 UTC (= June 25 00:00 CEST)).
|
||||
Both endpoints resolve to June 24 local (end is exactly midnight of June 25,
|
||||
which is June 24 22:00 UTC, so _lmu(June 25) = June 24 22:00 UTC is NOT < end_utc
|
||||
but equal → last_counted = June 24).
|
||||
first_counted = June 24.
|
||||
n_days = 1. Today (June 25) is past June 24 → elapsed.
|
||||
"""
|
||||
from unittest.mock import patch
|
||||
|
||||
eff_utc = _ams_midnight(2026, 6, 1)
|
||||
self._make_single_version_contract(energy_db, effective_from_utc=eff_utc)
|
||||
|
||||
start_utc = datetime(2026, 6, 24, 8, 0, 0, tzinfo=_UTC) # 10:00 CEST = mid-morning June 24
|
||||
end_utc = datetime(2026, 6, 24, 22, 0, 0, tzinfo=_UTC) # = June 25 00:00 CEST midnight
|
||||
|
||||
with patch.object(tz_module, "local_tz", return_value=_ams()):
|
||||
result = self._run_summarize_ams(energy_db, start_utc, end_utc)
|
||||
|
||||
daily_fixed = (9.87 + 9.87) / 30
|
||||
daily_credit = 600.0 / 365
|
||||
# Exactly 1 day: June 24 (start day, counted as full day; elapsed since today is June 25).
|
||||
assert abs(result["fixed_costs"] - daily_fixed * 1) < 1e-9, (
|
||||
f"FUE-T01: mid-morning to midnight window on one day should count 1 day; "
|
||||
f"expected {daily_fixed:.6f}, got {result['fixed_costs']}"
|
||||
)
|
||||
assert abs(result["credits"] - daily_credit * 1) < 1e-9, (
|
||||
f"FUE-T01: mid-morning to midnight window on one day should count 1 day of credits; "
|
||||
f"expected {daily_credit:.6f}, got {result['credits']}"
|
||||
)
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# 8. compute_closed_periods
|
||||
@@ -2263,3 +2447,266 @@ class TestMeterAwareComputePeriod:
|
||||
assert row.degraded is False, "All-zero deltas must not trigger the D6 guard"
|
||||
assert row.import_cost == 0.0
|
||||
assert row.net_cost == 0.0
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# FUE-T08. summarize — settlement offset (local 01:05)
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
|
||||
class TestSummarizeSettlementOffset:
|
||||
"""FUE-T08: daily fixed-fee/heffingskorting settled after local 01:05.
|
||||
|
||||
Reference date: June 26, 2026 AMS (CEST = UTC+2).
|
||||
- AMS midnight June 26 = June 25 22:00 UTC
|
||||
- Settlement threshold = June 25 22:00 + 01:05 = June 25 23:05 UTC
|
||||
= June 26 01:05 AMS
|
||||
- "before offset" now = June 26 00:30 AMS = June 25 22:30 UTC
|
||||
- "after offset" now = June 26 01:10 AMS = June 25 23:10 UTC
|
||||
|
||||
All tests monkeypatch both local_tz (Europe/Amsterdam) and
|
||||
``app.services.energy_cost.local_now`` to be fully deterministic.
|
||||
"""
|
||||
|
||||
# UTC instants used as "now":
|
||||
# June 25 22:30 UTC = June 26 00:30 AMS (before settlement threshold 23:05 UTC)
|
||||
_NOW_BEFORE = datetime(2026, 6, 25, 22, 30, 0, tzinfo=UTC)
|
||||
# June 25 23:10 UTC = June 26 01:10 AMS (after settlement threshold 23:05 UTC)
|
||||
_NOW_AFTER = datetime(2026, 6, 25, 23, 10, 0, tzinfo=UTC)
|
||||
|
||||
def _setup_single_version_contract(self, session: Session) -> None:
|
||||
"""Insert a manual contract effective Jan 1 2026 (covers all test dates)."""
|
||||
c = _make_contract(session, kind="manual", active=True)
|
||||
_make_version(session, c, _MANUAL_VALUES, effective_from=_ams_midnight(2026, 1, 1))
|
||||
session.commit()
|
||||
|
||||
def _run(
|
||||
self,
|
||||
session: Session,
|
||||
start_utc: datetime,
|
||||
end_utc: datetime,
|
||||
*,
|
||||
now_utc: datetime,
|
||||
) -> dict:
|
||||
"""Run summarize with AMS timezone and pinned local_now.
|
||||
|
||||
*now_utc* is converted to AMS before being used as the ``local_now``
|
||||
return value, so ``.date()`` yields the correct AMS local date.
|
||||
"""
|
||||
from unittest.mock import patch
|
||||
import app.services.energy_cost as _ec
|
||||
|
||||
now_ams = now_utc.astimezone(_ams())
|
||||
with patch.object(tz_module, "local_tz", return_value=_ams()):
|
||||
with patch.object(_ec, "local_now", return_value=now_ams):
|
||||
return summarize(session, start_utc, end_utc)
|
||||
|
||||
# --- AC1: before 01:05 → today not settled → fixed_costs/credits == 0 ---
|
||||
|
||||
def test_today_window_before_offset_yields_zero(self, energy_db: Session) -> None:
|
||||
"""AC1: At local 00:30 (before 01:05), today's window → credits == 0 and fixed_costs == 0.
|
||||
|
||||
Window: [June 26 AMS midnight, June 27 AMS midnight).
|
||||
now = June 26 00:30 AMS (before 01:05) → settled_cap = June 25.
|
||||
first_counted = June 26 > last_counted = June 25 → 0 days.
|
||||
"""
|
||||
self._setup_single_version_contract(energy_db)
|
||||
start = _ams_midnight(2026, 6, 26) # June 25 22:00 UTC
|
||||
end = _ams_midnight(2026, 6, 27) # June 26 22:00 UTC
|
||||
|
||||
result = self._run(energy_db, start, end, now_utc=self._NOW_BEFORE)
|
||||
|
||||
assert result["fixed_costs"] == 0.0, (
|
||||
"AC1: before settlement offset, today's fixed_costs must be 0; "
|
||||
f"got {result['fixed_costs']}"
|
||||
)
|
||||
assert result["credits"] == 0.0, (
|
||||
"AC1: before settlement offset, today's credits must be 0; "
|
||||
f"got {result['credits']}"
|
||||
)
|
||||
|
||||
# --- AC2: >= 01:05 → today settled → 1 day fixed/credits ---
|
||||
|
||||
def test_today_window_after_offset_yields_one_day(self, energy_db: Session) -> None:
|
||||
"""AC2: At local 01:10 (>= 01:05), today's window → 1 day of fixed/credits.
|
||||
|
||||
Window: [June 26 AMS midnight, June 27 AMS midnight).
|
||||
now = June 26 01:10 AMS (after 01:05) → settled_cap = June 26.
|
||||
first_counted = June 26 = last_counted → 1 day.
|
||||
"""
|
||||
self._setup_single_version_contract(energy_db)
|
||||
start = _ams_midnight(2026, 6, 26)
|
||||
end = _ams_midnight(2026, 6, 27)
|
||||
|
||||
result = self._run(energy_db, start, end, now_utc=self._NOW_AFTER)
|
||||
|
||||
daily_fixed = (9.87 + 9.87) / 30
|
||||
daily_credit = 600.0 / 365
|
||||
assert abs(result["fixed_costs"] - daily_fixed) < 1e-9, (
|
||||
"AC2: after settlement offset, today's fixed_costs must equal 1 day; "
|
||||
f"expected {daily_fixed:.6f}, got {result['fixed_costs']}"
|
||||
)
|
||||
assert abs(result["credits"] - daily_credit) < 1e-9, (
|
||||
"AC2: after settlement offset, today's credits must equal 1 day; "
|
||||
f"expected {daily_credit:.6f}, got {result['credits']}"
|
||||
)
|
||||
|
||||
# --- AC3a: cumulative window, before offset → today (June 26) not counted ---
|
||||
|
||||
def test_cumulative_before_offset_excludes_today(self, energy_db: Session) -> None:
|
||||
"""AC3: Cumulative window at 00:30 (before offset) excludes today from count.
|
||||
|
||||
Window: [June 24 AMS midnight, June 26 00:30 AMS).
|
||||
first_counted = June 24.
|
||||
last_counted (from window) = June 26 (lmu(June 26) = June 25 22:00 < 22:30).
|
||||
settled_cap = June 25 (before offset) → min(June 26, June 25) = June 25.
|
||||
Counted: June 24 + June 25 = 2 days (today June 26 excluded).
|
||||
"""
|
||||
self._setup_single_version_contract(energy_db)
|
||||
start = _ams_midnight(2026, 6, 24) # June 23 22:00 UTC
|
||||
end = self._NOW_BEFORE # June 25 22:30 UTC = June 26 00:30 AMS
|
||||
|
||||
result = self._run(energy_db, start, end, now_utc=self._NOW_BEFORE)
|
||||
|
||||
daily_fixed = (9.87 + 9.87) / 30
|
||||
daily_credit = 600.0 / 365
|
||||
assert abs(result["fixed_costs"] - daily_fixed * 2) < 1e-9, (
|
||||
"AC3 before offset: today (June 26) must not be counted; expected 2 days; "
|
||||
f"got {result['fixed_costs']}"
|
||||
)
|
||||
assert abs(result["credits"] - daily_credit * 2) < 1e-9, (
|
||||
"AC3 before offset: credits must be 2 days; "
|
||||
f"got {result['credits']}"
|
||||
)
|
||||
|
||||
# --- AC3b: cumulative window, after offset → today (June 26) counted ---
|
||||
|
||||
def test_cumulative_after_offset_includes_today(self, energy_db: Session) -> None:
|
||||
"""AC3: Cumulative window at 01:10 (after offset) includes today.
|
||||
|
||||
Window: [June 24 AMS midnight, June 26 01:10 AMS).
|
||||
first_counted = June 24.
|
||||
last_counted (from window) = June 26 (lmu(June 26) < 23:10 UTC).
|
||||
settled_cap = June 26 (after offset) → last_counted = June 26.
|
||||
Counted: June 24 + June 25 + June 26 = 3 days.
|
||||
"""
|
||||
self._setup_single_version_contract(energy_db)
|
||||
start = _ams_midnight(2026, 6, 24) # June 23 22:00 UTC
|
||||
end = self._NOW_AFTER # June 25 23:10 UTC = June 26 01:10 AMS
|
||||
|
||||
result = self._run(energy_db, start, end, now_utc=self._NOW_AFTER)
|
||||
|
||||
daily_fixed = (9.87 + 9.87) / 30
|
||||
daily_credit = 600.0 / 365
|
||||
assert abs(result["fixed_costs"] - daily_fixed * 3) < 1e-9, (
|
||||
"AC3 after offset: today (June 26) must be counted; expected 3 days; "
|
||||
f"got {result['fixed_costs']}"
|
||||
)
|
||||
assert abs(result["credits"] - daily_credit * 3) < 1e-9, (
|
||||
"AC3 after offset: credits must be 3 days; "
|
||||
f"got {result['credits']}"
|
||||
)
|
||||
|
||||
# --- AC4: past days always fully counted regardless of offset ---
|
||||
|
||||
def test_past_days_always_counted_regardless_of_offset(self, energy_db: Session) -> None:
|
||||
"""AC4: Past days (all before today) are fully counted even before 01:05.
|
||||
|
||||
Window: [June 20 AMS midnight, June 26 AMS midnight) — all before today.
|
||||
now = June 26 00:30 AMS (before offset) → settled_cap = June 25.
|
||||
last_counted (from window) = June 25 (lmu(June 26) = end_utc, not <).
|
||||
min(June 25, June 25) = June 25 → 6 days (June 20-25), all past.
|
||||
"""
|
||||
self._setup_single_version_contract(energy_db)
|
||||
start = _ams_midnight(2026, 6, 20) # June 19 22:00 UTC
|
||||
end = _ams_midnight(2026, 6, 26) # June 25 22:00 UTC
|
||||
|
||||
result = self._run(energy_db, start, end, now_utc=self._NOW_BEFORE)
|
||||
|
||||
daily_fixed = (9.87 + 9.87) / 30
|
||||
daily_credit = 600.0 / 365
|
||||
# June 20-25 = 6 days, all past — unaffected by settlement offset.
|
||||
assert abs(result["fixed_costs"] - daily_fixed * 6) < 1e-9, (
|
||||
"AC4: past days must be fully counted regardless of settlement offset; "
|
||||
f"expected 6 days = {daily_fixed * 6:.6f}, got {result['fixed_costs']}"
|
||||
)
|
||||
assert abs(result["credits"] - daily_credit * 6) < 1e-9, (
|
||||
"AC4: past credits must be 6 days; "
|
||||
f"got {result['credits']}"
|
||||
)
|
||||
|
||||
# --- AC5: cross-version segments still correct with settlement offset ---
|
||||
|
||||
def test_cross_version_with_settlement_offset(self, energy_db: Session) -> None:
|
||||
"""AC5: Cross-version day split is correct when settlement offset is active.
|
||||
|
||||
V1 covers June 24; V2 covers June 25+.
|
||||
Window: [June 24 AMS midnight, June 26 01:10 AMS).
|
||||
After offset (01:10) → settled_cap = June 26 → 3 days: V1=1, V2=2.
|
||||
|
||||
V1: network_fee=6, management_fee=6 → daily_fixed = 12/30
|
||||
heffingskorting=300 → daily_credit = 300/365
|
||||
V2: network_fee=12, management_fee=12 → daily_fixed = 24/30
|
||||
heffingskorting=600 → daily_credit = 600/365
|
||||
|
||||
Expected:
|
||||
fixed_costs = 1×(12/30) + 2×(24/30) = 0.4 + 1.6 = 2.0
|
||||
credits = 1×(300/365) + 2×(600/365) = 1500/365
|
||||
"""
|
||||
_VALUES_V1 = {
|
||||
"energy": {"buy": {"normal": 0.10, "dal": 0.10},
|
||||
"sell": {"normal": 0.05, "dal": 0.05},
|
||||
"energy_tax": 0.0, "ode": 0.0},
|
||||
"standing": {"network_fee": 6.0, "management_fee": 6.0},
|
||||
"credits": {"heffingskorting": 300.0},
|
||||
}
|
||||
_VALUES_V2 = {
|
||||
"energy": {"buy": {"normal": 0.20, "dal": 0.20},
|
||||
"sell": {"normal": 0.08, "dal": 0.08},
|
||||
"energy_tax": 0.0, "ode": 0.0},
|
||||
"standing": {"network_fee": 12.0, "management_fee": 12.0},
|
||||
"credits": {"heffingskorting": 600.0},
|
||||
}
|
||||
v1_from = _ams_midnight(2026, 6, 24) # June 23 22:00 UTC
|
||||
v2_from = _ams_midnight(2026, 6, 25) # June 24 22:00 UTC
|
||||
|
||||
c = _make_contract(energy_db, kind="manual", active=True)
|
||||
_make_version(energy_db, c, _VALUES_V1, effective_from=v1_from, effective_to=v2_from)
|
||||
_make_version(energy_db, c, _VALUES_V2, effective_from=v2_from)
|
||||
energy_db.commit()
|
||||
|
||||
start = _ams_midnight(2026, 6, 24) # June 23 22:00 UTC
|
||||
end = self._NOW_AFTER # June 25 23:10 UTC = June 26 01:10 AMS
|
||||
|
||||
result = self._run(energy_db, start, end, now_utc=self._NOW_AFTER)
|
||||
|
||||
expected_fixed = 1 * 12 / 30 + 2 * 24 / 30 # V1: 1 day, V2: 2 days
|
||||
expected_credits = 1 * 300 / 365 + 2 * 600 / 365
|
||||
assert abs(result["fixed_costs"] - expected_fixed) < 1e-9, (
|
||||
f"AC5: cross-version fixed_costs wrong; expected {expected_fixed}, "
|
||||
f"got {result['fixed_costs']}"
|
||||
)
|
||||
assert abs(result["credits"] - expected_credits) < 1e-9, (
|
||||
f"AC5: cross-version credits wrong; expected {expected_credits}, "
|
||||
f"got {result['credits']}"
|
||||
)
|
||||
|
||||
# --- AC6: return dict key-set unchanged ---
|
||||
|
||||
def test_return_dict_keys_unchanged(self, energy_db: Session) -> None:
|
||||
"""AC6: summarize() return dict keys are unchanged by the settlement offset."""
|
||||
self._setup_single_version_contract(energy_db)
|
||||
start = _ams_midnight(2026, 6, 26)
|
||||
end = _ams_midnight(2026, 6, 27)
|
||||
|
||||
result = self._run(energy_db, start, end, now_utc=self._NOW_AFTER)
|
||||
|
||||
expected_keys = {
|
||||
"currency", "metered_import", "metered_export", "metered_net",
|
||||
"fixed_costs", "credits", "total_payable", "period_count",
|
||||
"degraded_count", "days",
|
||||
}
|
||||
assert set(result.keys()) == expected_keys, (
|
||||
f"AC6: summarize() key set changed; expected {expected_keys}, "
|
||||
f"got {set(result.keys())}"
|
||||
)
|
||||
|
||||
+775
-74
File diff suppressed because it is too large
Load Diff
@@ -798,7 +798,7 @@ def test_meter_columns(energy_db):
|
||||
inspector = inspect(energy_db)
|
||||
columns = {col["name"]: col for col in inspector.get_columns("meter")}
|
||||
|
||||
non_nullable = {"id", "label", "commodity", "started_at", "reason", "created_at"}
|
||||
non_nullable = {"id", "uuid", "label", "commodity", "started_at", "reason", "created_at"}
|
||||
nullable = {"ended_at", "note"}
|
||||
|
||||
for col_name in non_nullable:
|
||||
@@ -810,11 +810,20 @@ def test_meter_columns(energy_db):
|
||||
assert columns[col_name]["nullable"], f"{col_name} should be nullable"
|
||||
|
||||
|
||||
def test_meter_uuid_unique_constraint(energy_db):
|
||||
"""meter.uuid must have a unique constraint."""
|
||||
inspector = inspect(energy_db)
|
||||
unique_constraints = inspector.get_unique_constraints("meter")
|
||||
unique_cols = [col for uc in unique_constraints for col in uc["column_names"]]
|
||||
assert "uuid" in unique_cols, "meter.uuid must have a unique constraint"
|
||||
|
||||
|
||||
def test_meter_orm_metadata():
|
||||
"""Meter must be registered in Base.metadata with correct field types."""
|
||||
assert "meter" in Base.metadata.tables, "meter not in Base.metadata"
|
||||
table = Base.metadata.tables["meter"]
|
||||
assert "id" in table.columns
|
||||
assert "uuid" in table.columns
|
||||
assert "label" in table.columns
|
||||
assert "commodity" in table.columns
|
||||
assert "started_at" in table.columns
|
||||
@@ -824,6 +833,14 @@ def test_meter_orm_metadata():
|
||||
assert "created_at" in table.columns
|
||||
|
||||
|
||||
def test_meter_uuid_unique_in_metadata():
|
||||
"""Meter.uuid must be declared unique and not nullable in ORM metadata."""
|
||||
table = Base.metadata.tables["meter"]
|
||||
col = table.columns["uuid"]
|
||||
assert col.unique, "Meter.uuid must be declared unique in ORM metadata"
|
||||
assert not col.nullable, "Meter.uuid must be NOT NULL in ORM metadata"
|
||||
|
||||
|
||||
def test_meter_insert_and_retrieve(energy_db):
|
||||
"""A Meter row can be inserted and retrieved with all fields intact."""
|
||||
now = datetime.now(tz=timezone.utc)
|
||||
|
||||
@@ -205,27 +205,58 @@ def test_register_provider_direct_call():
|
||||
def test_build_catalog_empty_with_no_devices(expose_db):
|
||||
"""build_catalog with no enabled modbus devices must contain no modbus entities.
|
||||
|
||||
The energy_cost provider is always registered and always produces its 6 entities
|
||||
(4 original + 2 daily) regardless of device state, so the catalog will not be empty.
|
||||
This test checks that no *modbus* entities are present when there are no enabled
|
||||
modbus devices.
|
||||
FUE-T05: the energy_cost provider now requires an active electricity meter.
|
||||
Without one, it returns [] and the catalog contains no energy entities.
|
||||
With one, it produces 6 entities.
|
||||
|
||||
This test verifies both cases:
|
||||
1. No modbus devices → no modbus entities.
|
||||
2. No active meter → no energy entities (provider returns []).
|
||||
3. After inserting an active meter → 6 energy entities present.
|
||||
"""
|
||||
from app.integrations.expose import build_catalog
|
||||
|
||||
# Case: no modbus devices, no active meter → catalog is empty.
|
||||
with Session(expose_db) as session:
|
||||
catalog = build_catalog(session)
|
||||
|
||||
# The modbus provider finds no enabled devices → no modbus entities.
|
||||
# The energy_cost provider always produces 6 entities, so the catalog is non-empty.
|
||||
modbus_entities = [e for e in catalog if e.entity.key.startswith("modbus.")]
|
||||
assert modbus_entities == [], (
|
||||
"Expected no modbus entities when no modbus devices are enabled"
|
||||
)
|
||||
|
||||
# The 6 energy_cost entities should always be present (4 original + 2 daily).
|
||||
energy_keys = {e.entity.key for e in catalog if e.entity.key.startswith("energy.")}
|
||||
assert len(energy_keys) == 6, (
|
||||
f"Expected exactly 6 energy_cost entities (4 original + 2 daily), got {energy_keys!r}"
|
||||
# No active electricity meter → energy-cost provider returns [] → no energy entities.
|
||||
energy_keys_no_meter = {e.entity.key for e in catalog if e.entity.key.startswith("energy.")}
|
||||
assert len(energy_keys_no_meter) == 0, (
|
||||
f"Expected 0 energy_cost entities (no active meter), got {energy_keys_no_meter!r}"
|
||||
)
|
||||
|
||||
# Insert an active electricity meter → provider should now produce 6 entities.
|
||||
from datetime import datetime, timezone
|
||||
now = datetime.now(tz=timezone.utc)
|
||||
with Session(expose_db) as session:
|
||||
from app.models.energy import Meter
|
||||
m = Meter(
|
||||
label="Test Meter for catalog",
|
||||
commodity="electricity",
|
||||
started_at=now,
|
||||
ended_at=None,
|
||||
reason="initial",
|
||||
note=None,
|
||||
created_at=now,
|
||||
)
|
||||
session.add(m)
|
||||
session.commit()
|
||||
|
||||
with Session(expose_db) as session:
|
||||
catalog_with_meter = build_catalog(session)
|
||||
|
||||
energy_keys_with_meter = {
|
||||
e.entity.key for e in catalog_with_meter if e.entity.key.startswith("energy.")
|
||||
}
|
||||
assert len(energy_keys_with_meter) == 6, (
|
||||
f"Expected exactly 6 energy_cost entities (4 original + 2 daily) with active meter, "
|
||||
f"got {energy_keys_with_meter!r}"
|
||||
)
|
||||
|
||||
|
||||
|
||||
@@ -381,6 +381,43 @@ class TestDeclareMeter:
|
||||
assert fetched.commodity == "gas"
|
||||
assert fetched.note == "Rotameter serial XYZ"
|
||||
|
||||
def test_declare_meter_generates_uuid(self, session: Session):
|
||||
"""declare_meter must auto-generate a non-empty uuid via ORM default."""
|
||||
import re
|
||||
UUID4_RE = re.compile(
|
||||
r"^[0-9a-f]{8}-[0-9a-f]{4}-4[0-9a-f]{3}-[89ab][0-9a-f]{3}-[0-9a-f]{12}$",
|
||||
re.IGNORECASE,
|
||||
)
|
||||
|
||||
m = declare_meter(
|
||||
session,
|
||||
label="Meter with UUID",
|
||||
started_at=_T0,
|
||||
reason="initial",
|
||||
)
|
||||
session.commit()
|
||||
|
||||
fetched = session.get(Meter, m.id)
|
||||
assert fetched is not None
|
||||
assert fetched.uuid is not None, "uuid must not be None after declare_meter"
|
||||
assert fetched.uuid != "", "uuid must not be empty"
|
||||
assert UUID4_RE.match(fetched.uuid), (
|
||||
f"uuid {fetched.uuid!r} does not look like a valid UUID v4"
|
||||
)
|
||||
|
||||
def test_declare_meter_each_gets_distinct_uuid(self, session: Session):
|
||||
"""Each declared meter must receive a distinct UUID (not duplicated)."""
|
||||
m1 = declare_meter(session, label="M1", started_at=_T0, reason="initial")
|
||||
session.commit()
|
||||
|
||||
t1 = _T0 + timedelta(days=10)
|
||||
m2 = declare_meter(session, label="M2", started_at=t1, reason="meter_swap")
|
||||
session.commit()
|
||||
|
||||
assert m1.uuid != m2.uuid, (
|
||||
f"Two declared meters must have distinct UUIDs; both got {m1.uuid!r}"
|
||||
)
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# 5. Different commodities are independent
|
||||
|
||||
@@ -217,6 +217,57 @@ class TestReadBlocks:
|
||||
|
||||
mock_client.close.assert_called_once()
|
||||
|
||||
@patch("app.integrations.modbus.driver.ModbusTcpClient")
|
||||
def test_default_function_code_uses_fc04_input_registers(
|
||||
self, mock_client_cls: MagicMock
|
||||
) -> None:
|
||||
"""With no function_code given, read_blocks uses FC04 (read_input_registers)."""
|
||||
mock_client = MagicMock()
|
||||
mock_client_cls.return_value = mock_client
|
||||
mock_client.connect.return_value = True
|
||||
mock_client.read_input_registers.return_value = _make_ok_response([0x4366, 0x3334])
|
||||
|
||||
read_blocks("127.0.0.1", 502, 1, [{"start": 0x0000, "count": 2}])
|
||||
|
||||
mock_client.read_input_registers.assert_called_once_with(0x0000, count=2, device_id=1)
|
||||
mock_client.read_holding_registers.assert_not_called()
|
||||
|
||||
@patch("app.integrations.modbus.driver.ModbusTcpClient")
|
||||
def test_function_code_3_uses_fc03_holding_registers(
|
||||
self, mock_client_cls: MagicMock
|
||||
) -> None:
|
||||
"""function_code=3 dispatches FC03 (read_holding_registers), e.g. DDSU666."""
|
||||
mock_client = MagicMock()
|
||||
mock_client_cls.return_value = mock_client
|
||||
mock_client.connect.return_value = True
|
||||
mock_client.read_holding_registers.return_value = _make_ok_response(
|
||||
[0x4366, 0x3334, 0x3F80, 0x0000]
|
||||
)
|
||||
|
||||
blocks = [{"start": 0x2000, "count": 4}]
|
||||
result = read_blocks("127.0.0.1", 502, 1, blocks, function_code=3)
|
||||
|
||||
assert result == {0x2000: 0x4366, 0x2001: 0x3334, 0x2002: 0x3F80, 0x2003: 0x0000}
|
||||
mock_client.read_holding_registers.assert_called_once_with(
|
||||
0x2000, count=4, device_id=1
|
||||
)
|
||||
mock_client.read_input_registers.assert_not_called()
|
||||
|
||||
@patch("app.integrations.modbus.driver.ModbusTcpClient")
|
||||
def test_invalid_function_code_raises_before_connecting(
|
||||
self, mock_client_cls: MagicMock
|
||||
) -> None:
|
||||
"""An unsupported function code is rejected without opening a connection."""
|
||||
mock_client = MagicMock()
|
||||
mock_client_cls.return_value = mock_client
|
||||
|
||||
with pytest.raises(ModbusDriverError, match="Unsupported read function code"):
|
||||
read_blocks("127.0.0.1", 502, 1, [{"start": 0, "count": 2}], function_code=16)
|
||||
|
||||
# No client should have been constructed or connected for a bad FC.
|
||||
mock_client_cls.assert_not_called()
|
||||
mock_client.connect.assert_not_called()
|
||||
|
||||
@patch("app.integrations.modbus.driver.ModbusTcpClient")
|
||||
def test_unit_id_passed_as_device_id(self, mock_client_cls: MagicMock) -> None:
|
||||
"""unit_id is forwarded as device_id= keyword argument (pymodbus 3.13.x)."""
|
||||
|
||||
Reference in New Issue