- Add CHINT DDSU666 profile (ddsu666.yaml): FC03 holding registers, voltage/
current/active power (kW)/reactive power (kvar)/PF/frequency, import+export
active energy. Word/byte order left at big-endian as a documented best guess
(manual has no float example) — to be confirmed on-device.
- Add DDSU666-Modbus-Protocol.md reference extracted from the official manual,
plus the source PDF (parity with the SDM120 reference).
- Generalize driver.read_blocks to dispatch FC03 (holding) or FC04 (input)
based on a function_code argument (default 4, SDM120 behaviour unchanged);
the code is validated before any connection is attempted.
- Wire profile.function_code through the CLI read command, the background
poller, and the device /test endpoint — previously the profile field was
declared but never honoured (read path was hardcoded to FC04).
- Tests: default -> FC04, function_code=3 -> FC03 holding, invalid FC rejected
before connecting.
Design for explicit meter lifecycle (epochs) so the register-difference
billing engine never computes a delta across a meter swap (2G->4G or house
move). Meter-centric (no Home entity); per-meter cumulative reset; retroactive
declaration with recompute; delta sanity guard as backstop. 7 atomic task cards.
- routes/api/energy.py + schemas/energy.py: GET prices (tibber points or manual
tariff, buy/sell consistent with the pricing strategies), GET costs (time
window + limit, ascending), GET costs/summary (summarize passthrough), GET
dsmr/latest, POST costs/recompute (idempotent, <=366d guard, CSRF), POST
tibber/test (three-state, token never echoed, CSRF).
- main.py registers router; OpenAPI re-exported; tests for all endpoints.
Rework the M5 design doc data model and add manual-testing surface:
- Two-layer model: rename energy_meters/energy_readings -> generic
modbus_device + modbus_reading; readings become a JSON payload blob
instead of a wide fixed-column table (aggregation via SQLite
json_extract, generated-column index as a future lever).
- Protocol knowledge moves to read-only YAML profiles (data+functions,
no OOP inheritance); deployment/config (friendly_name, unit_id, host)
stays on the device row; multiple devices share one profile.
- UUID = stable internal identity, also anchors HA discovery unique_id
(Z2M rename model); device metadata for HA derived from the profile.
- Naming scheme C: modbus_* / /api/modbus/devices at the data+API layer,
'Energy' as the first domain view in the frontend.
- New task M5-T01B: ConfigPage Accordion sectioning (avoids a second
in-page side nav conflicting with the T01 app sidebar).
- Manual testing: read-only modbus_cli 'probe' subcommand (FC03/04 only,
no register writes); mqtt/test now publishes a test message viewable
in MQTT Explorer; no MQTT CLI (manual verification via UI + HA).
Promote four now-decided directions from Future Ideas into a new
"下一阶段:已确定要做" section (roadmap altitude, not yet broken into task cards):
TOTP second factor for the public dashboard, frontend optimization (scope TBD),
MQTT / IoT integration, and a settings-page long-lived API token (PAT-style,
related to but distinct from M3's mobile OAuth). Future Ideas is now an empty,
purpose-stated bucket for not-yet-decided ideas.
Record TOTP (RFC 6238) as a deferred hardening idea for the now public-facing
Web dashboard: second factor on the single-admin login, with CLI-only password
reset and a CLI TOTP reset/recovery path that works even if the recovery codes
are lost (no lock-out dead end). Not M2.5, not scheduled — parked under a new
Future Ideas section.
- README: add 前端 v2 (React SPA) section (dev/build/codegen/hosting/gates),
update directory listing, drop stale Jinja descriptions
- architecture-overview: retire '不引入前后端分离' constraint; reflect SPA + JSON API
- roadmap: mark M2 done
- remove orphaned jinja2 dependency (recompile requirements*.txt; no other churn)
- delete empty tests/test_auth.py stub; drop dead _extract_csrf_token in test_api_data
- verified image still builds and app imports with the slimmer deps