M5-T03: add Modbus TCP driver, YAML profile framework, sdm120, modbus_cli
This commit is contained in:
@@ -0,0 +1,203 @@
|
||||
"""Modbus TCP driver — thin wrapper around pymodbus.
|
||||
|
||||
This module provides a single public function ``read_blocks`` that performs
|
||||
one or more FC04 (Read Input Registers) block reads against a Modbus TCP
|
||||
gateway and returns a flat ``dict[register_address -> 16-bit_value]`` map.
|
||||
|
||||
Design decisions
|
||||
----------------
|
||||
- **Only read function codes** (FC03/FC04) are exposed. There is no write path.
|
||||
- float32 decoding uses ``struct.unpack('>f', ...)`` directly rather than the
|
||||
pymodbus ``BinaryPayloadDecoder`` helper, which has had API churn across 3.x
|
||||
releases. Big-endian word order + big-endian byte order means the 4 raw bytes
|
||||
are already in standard network (big-endian) order.
|
||||
- ``ModbusTcpClient`` is used in synchronous mode (``connect()`` / ``close()``).
|
||||
The client is created fresh per call; this keeps the driver stateless and
|
||||
avoids threading concerns at the cost of one TCP handshake per read cycle.
|
||||
APScheduler jobs call this from a thread pool, so stateless is safer.
|
||||
- pymodbus 3.13.x uses ``device_id=`` as the slave-address keyword argument
|
||||
(renamed from ``slave=`` in earlier 3.x releases).
|
||||
|
||||
Exceptions
|
||||
----------
|
||||
``ModbusDriverError``
|
||||
Base exception for all driver-level errors.
|
||||
``ModbusConnectionError``
|
||||
Raised when the TCP connection to the gateway cannot be established or is
|
||||
lost during the read.
|
||||
``ModbusResponseError``
|
||||
Raised when the gateway responds with a Modbus exception frame or when the
|
||||
returned register count does not match the requested count.
|
||||
"""
|
||||
|
||||
from __future__ import annotations
|
||||
|
||||
import logging
|
||||
import struct
|
||||
from typing import TYPE_CHECKING
|
||||
|
||||
from pymodbus.client import ModbusTcpClient
|
||||
from pymodbus.exceptions import ConnectionException, ModbusException
|
||||
|
||||
if TYPE_CHECKING:
|
||||
from collections.abc import Sequence
|
||||
|
||||
logger = logging.getLogger(__name__)
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Custom exceptions
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
|
||||
class ModbusDriverError(RuntimeError):
|
||||
"""Base class for all Modbus driver errors."""
|
||||
|
||||
|
||||
class ModbusConnectionError(ModbusDriverError):
|
||||
"""Cannot connect to (or lost connection with) the Modbus TCP gateway."""
|
||||
|
||||
|
||||
class ModbusResponseError(ModbusDriverError):
|
||||
"""Modbus gateway returned an exception frame or an unexpected response."""
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Block definition type alias
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
#: A single read block: ``{"start": int, "count": int}``.
|
||||
Block = dict[str, int]
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Public API
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
|
||||
def read_blocks(
|
||||
host: str,
|
||||
port: int,
|
||||
unit_id: int,
|
||||
blocks: Sequence[Block],
|
||||
*,
|
||||
timeout: float = 3.0,
|
||||
) -> dict[int, int]:
|
||||
"""Read one or more contiguous register blocks via FC04 (input registers).
|
||||
|
||||
Parameters
|
||||
----------
|
||||
host:
|
||||
Hostname or IP address of the Modbus TCP gateway.
|
||||
port:
|
||||
TCP port (typically 502).
|
||||
unit_id:
|
||||
Modbus slave / unit address (the device's Meter ID for SDM120).
|
||||
blocks:
|
||||
Sequence of ``{"start": int, "count": int}`` dicts describing the
|
||||
contiguous register ranges to read. ``count`` is the number of
|
||||
16-bit registers (not bytes).
|
||||
timeout:
|
||||
TCP connect/read timeout in seconds (default 3 s).
|
||||
|
||||
Returns
|
||||
-------
|
||||
dict[int, int]
|
||||
Flat mapping of ``{register_address: 16-bit_register_value}`` for
|
||||
every register returned across all blocks.
|
||||
|
||||
Raises
|
||||
------
|
||||
ModbusConnectionError
|
||||
If the TCP connection to the gateway fails.
|
||||
ModbusResponseError
|
||||
If the gateway returns a Modbus exception frame or an unexpected
|
||||
number of registers.
|
||||
"""
|
||||
client = ModbusTcpClient(host, port=port, timeout=timeout)
|
||||
try:
|
||||
connected = client.connect()
|
||||
if not connected:
|
||||
raise ModbusConnectionError(
|
||||
f"Could not connect to Modbus gateway at {host}:{port}"
|
||||
)
|
||||
|
||||
registers: dict[int, int] = {}
|
||||
for block in blocks:
|
||||
start: int = block["start"]
|
||||
count: int = block["count"]
|
||||
_read_block(client, unit_id, start, count, registers)
|
||||
|
||||
return registers
|
||||
|
||||
except ConnectionException as exc:
|
||||
raise ModbusConnectionError(
|
||||
f"Connection to Modbus gateway {host}:{port} failed: {exc}"
|
||||
) from exc
|
||||
except ModbusException as exc:
|
||||
raise ModbusResponseError(f"Modbus protocol error: {exc}") from exc
|
||||
finally:
|
||||
client.close()
|
||||
|
||||
|
||||
def _read_block(
|
||||
client: ModbusTcpClient,
|
||||
unit_id: int,
|
||||
start: int,
|
||||
count: int,
|
||||
result: dict[int, int],
|
||||
) -> None:
|
||||
"""Read one block and merge into *result*. Raises on any error."""
|
||||
try:
|
||||
response = client.read_input_registers(start, count=count, device_id=unit_id)
|
||||
except ConnectionException as exc:
|
||||
raise ModbusConnectionError(
|
||||
f"Lost connection while reading registers 0x{start:04X}+{count}: {exc}"
|
||||
) from exc
|
||||
|
||||
if response.isError():
|
||||
raise ModbusResponseError(
|
||||
f"Modbus exception reading registers 0x{start:04X}+{count}: {response}"
|
||||
)
|
||||
|
||||
regs = response.registers
|
||||
if len(regs) != count:
|
||||
raise ModbusResponseError(
|
||||
f"Expected {count} registers from 0x{start:04X}, got {len(regs)}"
|
||||
)
|
||||
|
||||
for offset, value in enumerate(regs):
|
||||
result[start + offset] = value
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Decoding helpers
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
|
||||
def registers_to_float(hi_reg: int, lo_reg: int) -> float:
|
||||
"""Decode two 16-bit registers to a big-endian IEEE-754 float32.
|
||||
|
||||
The SDM120 (and most Modbus float devices) use big-endian word order:
|
||||
the high 16-bit register comes first, then the low register. Combined
|
||||
with big-endian byte order within each register, the raw 4-byte sequence
|
||||
is standard network-byte-order (big-endian) float32.
|
||||
|
||||
Parameters
|
||||
----------
|
||||
hi_reg:
|
||||
The first (higher-address-range, most-significant) 16-bit register.
|
||||
lo_reg:
|
||||
The second (lower-address-range, least-significant) 16-bit register.
|
||||
|
||||
Returns
|
||||
-------
|
||||
float
|
||||
The decoded IEEE-754 single-precision floating-point value.
|
||||
|
||||
Example
|
||||
-------
|
||||
>>> registers_to_float(0x4366, 0x3334)
|
||||
230.20001220703125
|
||||
"""
|
||||
raw = struct.pack(">HH", hi_reg, lo_reg)
|
||||
return struct.unpack(">f", raw)[0]
|
||||